3 Installation 3.4 Final work Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 Nozzle Changer Pipettenwechsler 06/2020 71 Fig.31: Menu: Nozzle configuration 3.4.2 Settings ► Switch the placement machine on at th…

100%1 / 80
3 Installation
3.4 Final work
70 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 Nozzle Changer Pipettenwechsler 06/2020
3.4 Final work
3.4.1 Taking the nozzle changer into operation
Fill the magazine outside the placement machine.
Only change a whole magazine at any time.
Open the key plate and place the nozzles in the nozzle holders.
Close the key plate so that the nozzles cannot drop out of the magazines.
NOTICE
Nozzles in magazines
Before you fill magazine, make sure that all the nozzles on the placement head have been
returned to their magazines.
NOTICE
Damaging the magazine
Do not allow components to drop onto the magazines. This can lead to a jamming of the
key plate.
Vacuum the magazines and free locations on a regular basis (see maintenance manual).
Fig.28: Menu for location nozzle changer
The nozzle changer functions can be found
in the menu .
Select the buttons for the menus
Magazine carrier configuration,
Magazine configuration and Nozzle
configuration (see below).
Fig.29: Menu: Magazine carrier configuration
Fig.30: Menu: Magazine configuration
3 Installation
3.4 Final work
Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 Nozzle Changer Pipettenwechsler 06/2020 71
Fig.31: Menu: Nozzle configuration
3.4.2 Settings
Switch the placement machine on at the main switch.
3.4.2.1 SIPLACE Pro
Fig.32: Configuration nozzle changers
Configure the nozzle changer in the setup in SIPLACE Pro.
3 Installation
3.4 Final work
72 Assembly Instructions / Montageanleitung SIPLACE SX1/SX2 Nozzle Changer Pipettenwechsler 06/2020
Fig.33: Manual configuration
Depending on your production concept, the nozzle changer configuration can be performed manu-
ally or calculated automatically during optimization of your placement programs.
Read also the help file in SIPLACE Pro.
3.4.2.2 Calibrating the nozzle changer
Switch the machine on again at the main switch and start it up.
Perform a complete reference run.
Fig.34: Select operator level
Select the button.
Select the button.
Switch over to the operator level Ma-
chine service.
ð The button will be shown.