00196932-02 SM S-Feeder Repair DE+EN multilang.pdf - 第106页
5 Checking and adjusting 2x8mm S-Feeder 5.3 Current input and direction o f rotation at the cover strip disposal motor 106 SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur

5 Checking and adjusting 2x8mm S-Feeder
5.3 Current input and direction of rotation at the cover strip disposal motor
SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur 105
8. Plug the adapter cable to slot 2.
9. Turn on the switch 2 up
10. Check the current consumption. Reference is 5-10
mA
11. Check that the motor rotates counter-clockwise.
CAUTION! With this test, no Feeders shall be
connected here to the test box!
5 Checking and adjusting 2x8mm S-Feeder
5.3 Current input and direction of rotation at the cover strip disposal motor
106 SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur

6 Checking and adjusting 3x8mm, 12-88mm S-Feeder
6.1 Overview: S-Feeder test set for 3x8mmS and 12-88mmS cover strip
SIPLACE S-Feeder Repair SIPLACE S-Förderer Reparatur 107
6
6 Checking and adjusting 3x8mm, 12-88mm S-Feeder
Checking and adjusting 3x8mm, 12-88mm S-
Feeder
6.1
6.1 Overview: S-Feeder test set for 3x8mmS and 12-88mmS cover strip
Overview: S-Feeder test set for 3x8mmS and 12-88mmS cover
strip
6.2
6.2 12-88mmS: Checking cover strip disposal motor, current input and the direction of rotation
12-88mmS: Checking cover strip disposal motor, current input
and the direction of rotation
1. Siplace S-Feeder Motor Tester
2. Extension bos with cable
3. power supply
4. 3x8mm cover strip motor complete
5. 12-88mm premounted cover strip motor
1. Set every toggle switch down and connect the motor to
the connector 1 on the extension box.
2. Turn on the S-Feeder Motor Tester.
3. Set the 5/30V switch to 5V. The switch position 30V is
suitable for endurance test.
4. Turn the "foil motor - switch 1" up
5. Check the current consumption of the motor tester.
Setpoint is 30 - 55mA.
6. Check the direction of rotation of the motor. It must ro
-
tate counter-clockwise.