00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第102页

Service manual vacuum check with closed nozzles Page 102 fr om 136 4.2.6 .3.5 Measurement with small hole in silicone hose . a.) W ith nozzl e 4235 b.) W ith nozzl e 4069 AC T AC T No features Open - val ue < Nom inal…

100%1 / 136
Service manual vacuum check with closed nozzles
Page
101 from 136
4.2.6.3.4 Measurement without vacuum hose (silicone hose disconnected)
a.) With nozzle 4235
b.) With nozzle 4069
NOM
ACT
ACT
Open-value < Nominal
Closed-value < Nominal
Holding < Nominal
Open-value < Nominal
Closed-value < Nominal
Holding < Nominal
NOM
Service manual vacuum check with closed nozzles
Page
102 from 136
4.2.6.3.5 Measurement with small hole in silicone hose.
a.) With nozzle 4235
b.) With nozzle 4069
ACT
ACT
No features
Open-value < Nominal
Closed-value < Nominal
Holding < Nominal
NOM
NOM
No features
Service manual vacuum check with closed nozzles
Page
103 from 136
4.2.6.3.6 Hole (passage to the star) for the holding vacuum on segment 1 soiled.
a.) With nozzles 4235
b.) With nozzles 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
NOM
No features
No features