00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第123页
Service manual vacuum check with closed nozzles Page 123 fr om 136 The values for the holding circuit m ust lie bet ween -700 mbar an d -950 mbar , ( depending on the a ltitude, the higher the locat ion the smaller th e …

Service manual vacuum check with closed nozzles
Page
122 from 136
• Choose Vacuum values, height values and scan values of the nozzles on the head (1).
• Choose the tab “Vacuum values” (2).
• Run „Measure vacuum values“ (3).
Evaluating the results:
NOTE
Error message
You must ignore the error message "Vacuum difference between open and closed is too low".
Difference between
open and closed
(Difference):
+/- 10 mbar
Not relevant!
Not relevant!

Service manual vacuum check with closed nozzles
Page
123 from 136
The values for the holding circuit must lie between
-700 mbar and -950 mbar,
(depending on the altitude, the higher the location the smaller the values)
Comparison: Measurement with type 2057 nozzles (calibration nozzles).

Service manual vacuum check with closed nozzles
Page
124 from 136
4.3.2 Vacuum tests on the CPP head
NOTE
Using the type 2069 closed (red) nozzles
Make sure that you deactivate nozzle scanning when using the red nozzles.
In order to provide guidance when troubleshooting, a number of different modifications were made to
a CPP head and vacuum tests were then carried out with type 2057 open nozzles (calibration
nozzles) and type 2069 closed (red) nozzles, and the results were compared.
The modifications were always carried out on segment 1.
4.3.2.1 Measurement without modification
a.) With type 2057 nozzles
NOMINAL