00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第129页
Service manual vacuum check with closed nozzles Page 129 fr om 136 4.3.2 .3.3 Measurement without filter disk. a.) W ith type 2057 no zzles b.) W ith type 2069 no zzles NOM AC T AC T Open value < nominal Closed v alue…

Service manual vacuum check with closed nozzles
Page
128 from 136
4.3.2.3.2 Measurement with half a filter disk (sealing membrane missing).
a.) With type 2057 nozzles
b.) With type 2069 nozzles
ACT
NOM
ACT
Open value < nominal
Closed value < nominal
Holding circuit < nominal
NOM
Closed value < nominal
No features or only
slight features

Service manual vacuum check with closed nozzles
Page
129 from 136
4.3.2.3.3 Measurement without filter disk.
a.) With type 2057 nozzles
b.) With type 2069 nozzles
NOM
ACT
ACT
Open value < nominal
Closed value < nominal
Holding circuit < nominal
NOM
Closed value < nominal
No features or only
slight features

Service manual vacuum check with closed nozzles
Page
130 from 136
4.3.2.3.4 Measurement without vacuum hose (silicone hose disconnected)
a.) With type 2057 nozzles
b.) With type 2069 nozzles
ACT
ACT
Open value < nominal
Closed value < nominal
Holding circuit < nominal
Open value < nominal
Closed value < nominal
Holding circuit < nominal
NOM
NOM