00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第88页

Service manual vacuum check with closed nozzles Page 88 fr om 136 4.2.5 .3.4 Measurement without vacuum hose (silicone hos e disconnected) a.) W ith type 1235 no zzles b.) W ith type 1069 no zzles NOM AC T AC T Open val …

100%1 / 136
Service manual vacuum check with closed nozzles
Page
87 from 136
4.2.5.3.3 Measurement without filter disk.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
NOM
ACT
ACT
No features
Open value < nominal
Closed value < nominal
Holding circuit < nominal
NOM
No features
Service manual vacuum check with closed nozzles
Page
88 from 136
4.2.5.3.4 Measurement without vacuum hose (silicone hose disconnected)
a.) With type 1235 nozzles
b.) With type 1069 nozzles
NOM
ACT
ACT
Open value < nominal
Closed value < nominal
Holding circuit < nominal
Open value < nominal
Closed value < nominal
Holding circuit < nominal
NOM
Service manual vacuum check with closed nozzles
Page
89 from 136
4.2.5.3.5 Measurement with small hole in silicone hose.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
No features
Open value < nominal
Closed value < nominal
ACT
ACT
NOM
NOM
Holding circuit < nominal
No features