00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第106页

Service manual vacuum check with closed nozzles Page 106 fr om 136 4.2.6 .3.9 2 screws on the holdi ng circuit not tightened (screws at 10 & 3; screw at 17 is tightened) . a.) W ith nozzles 1235 AC T NOM in the vici …

100%1 / 136
Service manual vacuum check with closed nozzles
Page
105 from 136
4.2.6.3.8 Hole for the vacuum in holding circuit on segment 1 soiled.
a.) With nozzles 4235
b.) With nozzles 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
Open-value < Nominal
Closed-value < Nominal
NOM
No features
Service manual vacuum check with closed nozzles
Page
106 from 136
4.2.6.3.9 2 screws on the holding circuit not tightened (screws at 10 & 3; screw at 17 is
tightened).
a.) With nozzles 1235
ACT
NOM
in the vicinity of the loose
screws
Holding circuit < nominal
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal
Service manual vacuum check with closed nozzles
Page
107 from 136
b.) With nozzles 1069
NOM
ACT
in the vicinity of the loose
screws
Holding circuit < nominal
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal