00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第85页

Service manual vacuum check with closed nozzles Page 85 fr om 136 4.2.5 .3 Measuremen ts w ith modifications 4.2.5 .3.1 Measurement with filter disk covered (soil ed). a.) W ith type 1235 no zzles b.) W ith type 1069 no …

100%1 / 136
Service manual vacuum check with closed nozzles
Page
84 from 136
4.2.5.2 Overview of possible causes and effects
Service manual vacuum check with closed nozzles
Page
85 from 136
4.2.5.3 Measurements with modifications
4.2.5.3.1 Measurement with filter disk covered (soiled).
a.) With type 1235 nozzles
b.) With type 1069 nozzles
NOM
NOM
ACT
ACT
Holding circuit > nominal.
Open value > nominal
No features
No features
Service manual vacuum check with closed nozzles
Page
86 from 136
4.2.5.3.2 Measurement with half a filter disk (sealing membrane missing).
a.) With type 1235 nozzles
b.) With type 1069 nozzles
NOM
NOM
ACT
ACT
Open value < nominal
Closed value < nominal
No features
Holding circuit < nominal
No features