00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第93页
Service manual vacuum check with closed nozzles Page 93 fr om 136 4.2.5 .3.9 2 screws on the holdi ng circuit not tightened (screws at 10 & 3; screw at 17 is tigh te ned). a.) W ith type 1235 no zzles AC T in the vic…

Service manual vacuum check with closed nozzles
Page
92 from 136
4.2.5.3.8 Hole for the vacuum in holding circuit on segment 1 soiled.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
ACT
ACT
Holding circuit < nominal
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM
NOM
No features

Service manual vacuum check with closed nozzles
Page
93 from 136
4.2.5.3.9 2 screws on the holding circuit not tightened (screws at 10 & 3; screw at 17 is
tightened).
a.) With type 1235 nozzles
ACT
in the vicinity of the loose
screws
Holding circuit < nominal
NOM
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal

Service manual vacuum check with closed nozzles
Page
94 from 136
b.) With type 1069 nozzles
ACT
NOM
in the vicinity of the loose
screws
Holding circuit < nominal
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal