00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第117页
Service manual vacuum check with closed nozzles Page 117 fr om 136 4.2.7 .3.7 Hole for the air kiss in ho lding circuit on segment 1 soiled . a.) W ith nozzles typ e 423 5 b.) W ith nozzles type 4069 AC T NOM AC T Holdin…

Service manual vacuum check with closed nozzles
Page
116 from 136
4.2.7.3.6 Hole (passage to the star) for the holding vacuum on segment 1 soiled.
a.) With nozzles type 4235
b.) With nozzles type 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
NOM
No features
No features

Service manual vacuum check with closed nozzles
Page
117 from 136
4.2.7.3.7 Hole for the air kiss in holding circuit on segment 1 soiled.
a.) With nozzles type 4235
b.) With nozzles type 4069
ACT
NOM
ACT
Holding < nominal
Holding < nominal
Open value < nominal
Open value < nominal
NOM
No features

Service manual vacuum check with closed nozzles
Page
118 from 136
4.2.7.3.8 2 screws on the holding circuit not tightened (screws at 10 & 3; screw at 17 is
tightened).
a.) With nozzles type 4235
ACT
NOM
in the vicinity of the loose
screws
Holding circuit < nominal
in the vicinity of the
loose screws
open < nominal
closed < nominal
Loose Screws