00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E.pdf - 第104页
Service manual vacuum check with closed nozzles Page 104 fr om 136 4.2.6 .3.7 Hole for t he air kiss in holding circuit on segment 1 soiled . a.) W ith nozzles 4235 b.) W ith nozzles 4069 AC T NOM AC T Holding < Nomin…

Service manual vacuum check with closed nozzles
Page
103 from 136
4.2.6.3.6 Hole (passage to the star) for the holding vacuum on segment 1 soiled.
a.) With nozzles 4235
b.) With nozzles 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
NOM
No features
No features

Service manual vacuum check with closed nozzles
Page
104 from 136
4.2.6.3.7 Hole for the air kiss in holding circuit on segment 1 soiled.
a.) With nozzles 4235
b.) With nozzles 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
Open-values < Nominal
Closed-values < Nominal
Open-value < Nominal
Closed-value < Nominal
NOM

Service manual vacuum check with closed nozzles
Page
105 from 136
4.2.6.3.8 Hole for the vacuum in holding circuit on segment 1 soiled.
a.) With nozzles 4235
b.) With nozzles 4069
ACT
NOM
ACT
Holding < Nominal
Holding < Nominal
Open-value < Nominal
Closed-value < Nominal
NOM
No features