3 … Troubleshooting  Actuating a Programmer —27— If you are experiencing low throughput during normal operation, an d your PPH when run- ning the PV-Kit job is . . . . . . gr eatly reduced from the original, then contac…

100%1 / 58
Data I/O
FLX500 Chptr 3
—26—
Rerunning the PV-Kit
If you suspect a problem with the FLX500, you
can check to see if the problem is the FLX500 and
not a device, algorithm, or power source, by
rerunning the PV-Kit job. All hardware required
to run the PV-Kit job, including 16 devices, came
with the FLX500. Contact Data I/O for informa-
tion about ordering replacement parts for the
PV-Kit.
NOTE: Be sure the Socket Adapters are
clean before running the PV-Kit job.
1. Rerun the PV-Kit job. For instructions see
Run PV-Kit on page 5.
2. Read the Throughput displayed on the sta-
tistics screen on the monitor by tapping the
Statistics button on the Run Window.
Record the PPH in the PV-Kit Performance
chart on page 47.
Figure 14—The Statistics Window displays
Throughput, often abbreviated as PPH.
If the PPH is the same as when the machine was
new (approximately 500 PPH) then you can
eliminate many of the possible error causes.
3 … Troubleshooting Actuating a Programmer
—27—
If you are experiencing low throughput during
normal operation, and your PPH when run-
ning the PV-Kit job is . . .
. . . greatly reduced from the original, then contact
Data I/O or your local representative. For contact
information see Customer Support on page 35.
. . . the same as when it was new, then you can gen-
erally eliminate suspected problems with the
FLX500. The problem may have to do with your
device, algorithm, job file, etc. (things related to
device or job file).
Actuating a Programmer
Without Power
If you have a Programmer Module that is not
installed on an FLX500 and still has a Socket
Adapter in it, the Actuator Plate should be in the
up position for removal of the Socket Adapter. If
it is in the down position, you can remove the
adapter by manually actuating the Actuator
Plate to the up (sockets closed) position.
To manually actuate the plate on a programmer
without power:
1. Lay the Programmer Module on its side to
access the bottom.
2. With a flat screwdriver, rotate the actuator
screw shown in Figure 15 as many revolu-
tions as necessary to free the Actuator Plate
so it can be slid out.
Data I/O
FLX500 Chptr 3
—28—
Figure 15—The bottom of a Programmer Module
allows access to the actuating screws when power to
the programmer is unavailable.
3. Slide the Actuator Plate out from the pro-
grammer.
4. Remove the Socket Adapter in the usual
way. For help removing the adapter, see the
on-screen Help.
Fiducial Scan Errors
If the FLX500 fails to program after the PNP Head
scans the modules, there may be a problem with
the scanning.
NOTE: For accurate scanning, the fiducials
and sensors must be clean and the FLX cover
must be closed. For cleaning instructions,
see Cleaning the Fiducials and Sensors on
page 12.
For this check only, open the cover and view the
PNP Head optic sensor during scanning. The
digital display should read:
1000+ on the top surface (shiny, metal) of the
module
0 — 500 within the fiducial slot