NR_Mechanischer_Stopper.pdf - 第128页

Assembly Instructions PCB Stopper Sin gle Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series Edition 06/2007 128

100%1 / 238
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
127
11.2.5 Use as prescribed
The product must only be used for its intended purposes as described in the catalogs and
technical descriptions, namely the placement of SMD components, and only with the third-party
equipment and components recommended or permitted by Siemens A&D. Use for a different or
extended purpose is not prescribed.
If the product is not used as prescribed, Siemens accepts no liability for any damage that may
occur and does not guarantee that the components will work properly and without problems.
Use as prescribed also includes compliance with all the instructions in the user manual.
For the product to operate correctly and reliably, it must have been transported, stored, erected
and assembled correctly and must be operated and maintained with care.
11.2.6 Failure to use as prescribed
Failure to use the product as prescribed can result in both danger to life and limb and material
damage. For this reason any use that is not prescribed is not allowed. If the product is not used
as prescribed, Siemens accepts no liability for any damage that may occur and does not
guarantee that the components will work properly and without problems.
Failure to use the option as prescribed includes, for example:
operation with other machines than the approved machine types by Siemens AG.
operation of this option within an environment differing from that one specified in this manual.
use of the placement machine with the installed option by unqualified personnel.
11
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
128
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
129
12 Assembly Instructions PCB Stopper
SIPLACE S-27HM / HS-60 / D4 / D3 /
HF- / X-Series
ATTENTION: This internal document describes service work to SIPLACE placement machines,
which may only be performed by specially trained Siemens service technicians. 12
12
The description of the installation process is based on the example of a dual conveyor.Single con-
veyor installation is carried out similarly. Attention is drawn to significant differences.
12
12.1 Functional description
Fig. 106
The optional mechanical stopper was developed for placement machines of the X-Series, HF-Se-
ries, HS-60, D3, D4 and S-27 HM. These are fitted as standard with modular PCB conveyors and
laser light barriers for stopping the printed circuit boards.
Placement machines of the types HS-50, F5 HM and S-25 HM on the other hand have a PCB con-
veyor with mechanical stopper. 12
Stopper, basic unit
Rotating cylinder
Sonar sensor
Stopper
Stopper sensor top/bottom