Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
209
O For the HF-/X-Series (mounting tub 604 mm) with dual and single conveyor, the following dis-
tances must be observed:
Fig. 190 Distances for the trailing cable distance blocks (HF-Series, X-Series, D3)
For a dual conveyor, stick an additional "Distance block for energy chain, complete" in the mid-
dle between the two distance blocks for better movement of the trailing cable. [03043432-xx]. 15
O Using the adhesive tape, stick the distance block of the trailing cable onto the mounting tub
under the second conveyor side parallel to the guide rail (or to the width adjustment) in such a
way that the trailing cable stands vertical when the guide rail is installed.
Conveyor track 2 Conveyor track 1
Distance block for energy chain
Left
conveyor side
Right
conveyor side
340 mm 260 mm
440 mm
160 mm
Transport direction
Left side of
mounting tub
Right side of
mounting tub
604 mm

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
210
O For a single conveyor, stick the distance block onto the position of conveyor track 1. The stop-
per must be able to slide over the entire conveyor width. The distance block stuck on the floor
of the mounting tub must be positioned so that the trailing cables run parallel to the guide strip
of the stopper. If other cables prevent this, they must be repositioned.
Fig. 191
O Attach the guide strip to the holders with two cylinder head bolts (hexagon socket head
M5 x 20 DIN 912).
15
Caution, crash hazard:
– It is essential to ensure that the stopper and the trailing cables do not collide with the width
adjustment or its conveyor belt.
– The stoppers must be able to slide over the entire conveyor width.
– The trailing cable of conveyor track 1 must run exactly on the trailing cable of the stopper in
conveyor track 2 and must not tilt to the side.
– The distance between the two distance blocks should be approx. 100 mm.
– The laying of cables and tubing is described in a later section for functional reasons.

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
211
15.3.3 Laying cables and pneumatic tubing
15.3.3.1 Complete overview
Fig. 192 Cable laying HF-/X-Series/D3
Red lines:
Power and data lines 15
Blue lines:
Pneumatic power supply 15