Introduction 1.3.4 Validity of Document Other Instructions Maintenance Manual SIPLACE Placement Heads CPP, C &P20, Twin 11 Always place the modu les on a co nductive surface (table with an ESD coating, co ndu ctive E…

Introduction
Other Instructions 1.3.1 Environmentally-Friendly Disposal of Materials and Components
10 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
1.3
1.3 Other Instructions
Other Instructions
1.3.1
1.3.1 Environmentally-Friendly Disposal of Materials and Components
Environmentally-Friendly Disposal of Materials and Components
SIPLACE products are manufactured using only materials and parts that can be easily separated and
disposed of in an environmentally-friendly way.
1.3.2
1.3.2 Use of Original SIPLACE Accessories and Spare Parts
Use of Original SIPLACE Accessories and Spare Parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety and
will invalidate the liability for any consequential damage.
1.3.3
1.3.3 ESD Guidelines
ESD Guidelines
1.3.3.1
1.3.3.1 Definition of ESD
Definition of ESD
1.3.3.2
1.3.3.2 Important Measures to Protect Against Static Charging
Important Measures to Protect Against Static Charging
► Most plastics can easily become charged and must therefore be kept away from at-risk components.
► Always ensure that people, the workplace and packaging are safely earthed when handling electro-
static sensitive components.
1.3.3.3
1.3.3.3 Handling ESD Modules
Handling ESD Modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other work.
If it is necessary, make sure that you do not touch the pins or printed conductors when you pick up flat
modules.
Do not touch components unless
▪ You are constantly earthed by an ESD wrist strap or
▪ You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a conductive
and earthed object immediately before you touch the module (such as unpainted parts of a switch cab-
inet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g. plastic
films, insulating table surfaces or items of clothing made from synthetic fibers.
NOTICE
Observe the applicable regulations
The company operating the system has sole responsibility for the proper, environmentally-
friendly disposal of machines, working materials, consumables and wear parts.
► Please observe your national statutory provisions for waste disposal and environmental
protection.
Almost all of the modules in use today are equipped with highly integrated MOS blocks and compo-
nents. The manufacturing techniques used mean that these electronic components are extremely sen-
sitive to overvoltage and thus to electrostatic discharge.
The abbreviation for such modules is 'ESD' (Electrostatic Sensitive Device). This is
used internationally, although the German abbreviation 'EGB' may also be seen. The
following symbol on cabinet rating plates, racks or packaging indicates that compo-
nents which are sensitive to electrostatic discharge have been used and thus that the
modules concerned are also touch-sensitive.
ESDs can be destroyed by voltages and power levels that are far below the level that can be perceived
by humans. Such voltages occur if a person touches a component or module without earthing them-
selves. Components that are exposed to such overvoltages do not generally appear to be defective im-
mediately - incorrect behavior starts after the component or module has been in operation for some
time.

Introduction
1.3.4 Validity of Document Other Instructions
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 11
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD foam,
ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10 cm away
from the screen.
1.3.3.4
1.3.3.4 Measurements and Modifications to ESD Modules
Measurements and Modifications to ESD Modules
Measurements of the assemblies may only be taken if
▪ The measuring device has been grounded (e.g. via protective conductor) or
▪ The measuring head of the potential-free measuring device has been briefly discharged before
measurement (e.g. touching blank metal control unit housing).
► Always use an earthed soldering iron if you carry out any soldering work.
1.3.3.5
1.3.3.5 Dispatching ESD Modules
Dispatching ESD Modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags or met-
al sleeves) and dispatch them in conductive packaging.
► If the packaging is not conductive, place the modules in a conductive envelope before packaging.
Use conductive foam rubber, ESD bags, domestic aluminum foil or paper, for example. NEVER use
plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or short-
circuit the battery terminals and, if necessary, first cover the terminals with insulating tape or mate-
rial.
1.3.4
1.3.4 Validity of Document
Validity of Document
This document contains maintenance work instructions for all SIPLACE placement heads of type
C&P20, CPP, and Twin.
▪ If the work required should differ from the standard procedure, this will be indicated with reference
to the version and delivery state.
▪ Diagrams should be seen as examples e.g. a different paint finish does not mean that the following
information only applies to the type shown.
1.3.5
1.3.5 Release History
Release History
Document
SIPLACE placement heads CPP, C&P, Twin
Maintenance Manual
Release Changes
06/2014 First edition
Introduction
Staff Qualifications and Training 1.3.6 SIPLACE on the World Wide Web (WWW)
12 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
1.3.6
1.3.6 SIPLACE on the World Wide Web (WWW)
SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
► You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can also access the
SIPLACE User Group
. Here you can call up spe-
cial information about our placement systems e.g.
▪ Technical documentation,
▪ Technical information,
▪ Spare parts lists etc.
Registration for the user group is very simple:
► Click on the Register link.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.
1.4
1.4 Staff Qualifications and Training
Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op-
eration and maintenance of automatic placement systems and add-on devices and are suitably qualified,
e.g.:
▪ Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
▪ Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord-
ance with normal safety standards.
▪ Have received first aid training.