00197551-01_MM_CPP-CP-Twin_Kunde_en.pdf - 第21页
Maintenance tasks for CPP Preparatory Steps Maintenance Manual SIPLACE Placement Heads CPP, C &P20, Twin 21 Preparing the Placement Head ► Dismantle the placement head and remove it from th e placement m achine. For …

Maintenance tasks for CPP
Preparatory Steps
20 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
3.3
3.3 Preparatory Steps
Preparatory Steps
Preparing the Head Mount
Preparing the Head Mount
► Assemble the head mount. For details, refer to the assembly instructions "Universal placement head
mounting rack" [DE+EN: 00196371-xx].
Vacuum test
► Set the nozzles for the current nozzle configuration down in the nozzle changer.
► Before you begin maintenance work, perform a vacuum test. Use the calibration nozzles 2057 for
this. If vacuum value irregularities occur at certain segments, take a closer look at these during main-
tenance work. Note down the numbers of the problematic segments for later reference.
Spare parts Item no. HMK
Holding circuit assembly for CPP version <= 04 03055424- xx
Holding circuit assembly for CPP version >= 05 03081381- xx
Silencer assembly CPP 03061440- xx
Nozzle magazine type 20xx 03066107- xx
CAUTION
Perform a software update if required
Due to an incorrect value in the station software, the request to perform maintenance may be
shown too late or not at all.
► From SW 706.01 SP2 (or 705.05.SP2) onwards, the request is shown correctly.
► For older software, perform a software update. For details, refer to the technical information
"Maintenance level for DP unit on CPP head incorrect in the software" [DE: TI2013-06D02]
[EN: TI2013-06E02].
CAUTION
ESD
► Connect the assembly mount ESD connection to an ESD connection at the workplace.
► Always observe the ESD regulations described in the user manual.
NOTICE
Error messages
The following error messages could indicate that the holding circuit is dirty:
► During the reference run: "FM 30614 Holding circuit vacuum for nozzle of specified type too
small"
► During placement: "FM 30565 Measured pressure in holding circuit is too low"

Maintenance tasks for CPP
Preparatory Steps
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 21
Preparing the Placement Head
► Dismantle the placement head and remove it from the placement machine. For details, refer to the
service manual for your machine.
Use the FHE function if possible.
► Fit the placement head onto the head mount.
Dismantling the Front Plate
► Dismantle the front plate. For details, refer to the "Service manual CPP".
Multipette
Multipette
► Prepare the multipette. For more information about this, read section "9 Handling the Multipette"
[ ➙ 89]. Also observe the following instructions:
Color-coding of dosage devices and lubricants
► Fit the protective cap onto the component sensor for
the placement head.
CAUTION
Do not combine lubricants!
Contamination (combination) of lubricants can affect the service life of the bearings!
► Only use the combitip specifically marked for each lubricant, to avoid combining the lubri-
cants.
Color Lubricant Application
Black Black combitip
Klüberalfa DH 3-100
Driver bearing
Blue Blue combitip
Lubcon Thermoplex ALN 1001/00 50 ml
Segment guide/Z linear guide
Yellow Yellow combitip
Klüber oil GEM 1 220 N
Support roller
Green Green combitip
Isoflex Topas NCA 5051
Star bearing

Maintenance tasks for CPP
Overview of Lubrication Points
22 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
3.4
3.4 Overview of Lubrication Points
Overview of Lubrication Points
Driver bearing
1 x 1 µl Klüberalfa DH 3-100 (black combitip)
per driver bearing
DP segment guide
2 x 2 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove at each segment
Z linear guide
2 x 4 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove