00197551-01_MM_CPP-CP-Twin_Kunde_en.pdf - 第64页
Maintenance Tasks for Twin Performing Maintenance Tasks 5.4.2 Cleaning the Sleeve and Nozzl e Seat 64 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 5.4.2 5 . 4 . 2 C le a n in g t h e S le e v e a n d N…

Maintenance Tasks for Twin
5.4.1 Replacing the Pressure Control Valve Preparatory Steps
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 63
5.3
5.3 Preparatory Steps
Preparatory Steps
Preparing the Head Mount
Preparing the Head Mount
► Assemble the head mount. For details, refer to the assembly instructions "Universal placement head
mounting rack" [DE+EN: 00196371-xx].
Preparing the Placement Head
► Dismantle the placement head and remove it from the placement machine. For details, refer to the
service manual for your machine.
Use the FHE function if possible.
► Fit the placement head onto the head mount.
5.4
5.4 Performing Maintenance Tasks
Performing Maintenance Tasks
5.4.1
5.4.1 Replacing the Pressure Control Valve
Replacing the Pressure Control Valve
Replacin g the Pres sure Contr ol Valve
Replacing the Pressure Control Valve
➢ The placement head must be removed for this maintenance task.
► Replace the pressure control valve. Read the service manual for your placement head for more in-
formation.
CAUTION
ESD
► Connect the assembly mount ESD connection to an ESD connection at the workplace.
► Always observe the ESD regulations described in the user manual.
NOTICE
Recommendation
We recommend that you have an additional pressure control valve available, so that this can
be easily replaced during head maintenance.
The actual cleaning of the removed pressure control valve can be performed later on.
► For more information about this, read section "6 Maintenance Tasks for Pressure Control
Valve" [ ➙ 65].

Maintenance Tasks for Twin
Performing Maintenance Tasks 5.4.2 Cleaning the Sleeve and Nozzle Seat
64 Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin
5.4.2
5.4.2 Cleaning the Sleeve and Nozzle Seat
Cleaning the Sleeve and Nozzle Seat
5.4.3
5.4.3 Cleaning/Replacing the Additional Volume Filter
Cleaning/Replacing the Additional Volume Filter
Sleeve (Twin shown as example)
► Spray a small amount of Teflon oil on a lint-free cloth
and clean the sleeve and nozzle seat.
Alternatively you can also use a SIPLACE cleaning
cloth.
► Carefully blow through the nozzle.
► Repeat these steps on the second Twin module if
necessary.
Filter (example of Twin shown)
► Unscrew the lid (1) of the filter.
NOTICE!
If the filter is difficult to access, use the long-nosed pliers
to help you.
► Remove the filter (2).
► Clean the filter by blowing compressed air through it.
► Check the filter for damage.
► If it is damaged replace it with a new one.
► Screw the filter tight again.
► Repeat these steps on the second Twin module if
necessary.

Maintenance Tasks for Pressure Control Valve
Tools, Consumables, Spare and Wear Parts
Maintenance Manual SIPLACE Placement Heads CPP, C&P20, Twin 65
6
6 Maintenance Tasks for Pressure Control Valve
Maintenance Tasks for Pressure Control Valve
6.1
6.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
The following lists contain all necessary consumable materials, wear and spare parts plus tools for per-
forming maintenance tasks to the pressure control valve.
HMK = Included in Head Maintenance Kit
See also
8.2 Tools, Consumables, Spare and Wear Parts [ ➙ 81]
Consumables Item no. HMK
Lint-free cloth, KM wipe 03082092- xx
Ethanol
Isopropanol – IPA can be used as an alternative.
Cleaning sticks 00388764- xx X
Distilled water
Compressed air
ISOFLEX Topas 5051 50 ml 03078517- xx
Tools Item no. HMK
ESD wriststrap TYP.OK/WRS 00320279- xx
Allan key set 0.7 – 2 mm 00320265- xx X
Torque interchangeable blades 3mm hexagonal 03109522- xx X
Torque screwdriver ESD 0.1-0.6 Nm 00386132- xx X
Torque interchangeable blades 1.5 mm, hexagonal 00386135- xx X
Torque interchangeable blades 2 mm, hexagonal 00386136- xx X
Torx blade TX6 150 03076647- xx X
Press-fit blade for Phillips screwdriver size 1
Slotted screwdriver size 0
Philips inset PH1 03075861- xx
Wrench socket size 8
Tweezers 150 mm pointed, angled 00096487- xx