RX-8_SPE_EN.pdf - 第34页

30 8-2 Input a nd output s ignal interf ace 24V 搬出要求入力信号 ピン 番号 : 1( フロント側) ピン番号:9(リア側) 搬出要求信号コモン ピン番号:2( フロント側) ピン番号:10 (リア 側 ) 下流側装置 搬出許可出力信号 ピン 番号: 3 (フロント 側 ) ピン番号:11( リア 側) 搬出許可信号 コモン ピン 番号:4(フロント 側) ピン番号:12(リア側) 24V…

100%1 / 38
29
8. Interface
8-1 Electric interface
8-1-1 Kinds and meanings of electrical signals
The conceptual diagram of the electrical signals sent/received to/from both the RX-8 and an
upstream/downstream device is shown in the figure “Conceptual diagram of electrical signal connection
below.
The electrical signals transmitted between the RX-8 and an upstream-side device, and , and those
between the RX-8 and a downstream-side device, and , are shown below.
a) The electrical signal is called a “board eject request input signal (or Board Available In)” and
receives a PWB eject request from an upstream device.
b) The electrical signal is called a “board eject permission output signal (or Ready Out)” and
causes a PWB to be ejected to an upstream device.
c) The electrical signal is called a “board eject request output signal (or Board Available Out)” and
requests a downstream device to eject a PWB.
d) The electrical signal is called a “board eject permission input signal (or Ready In)” and receives
PWB eject permission from a downstream device.
Conceptual diagram of electrical signal connection
下流側装置
マウンター
上流側装置
Downstream
device
RX-8
Upstream
device
30
8-2 Input and output signal interface
24V
搬出要求入力信号
ピン
番号
1(
フロント側)
ピン番号:9(リア側)
搬出要求信号コモン
ピン番号:2(
フロント側)
ピン番号:10
(リア
下流側装置
搬出許可出力信号
ピン
番号:
(フロント
ピン番号:11(
リア
側)
搬出許可信号
コモン
ピン
番号:4(フロント
側)
ピン番号:12(リア側)
24V
搬出許可入力信号
ピン番号:3(フロント側
ピン
番号:11(リア側)
搬出許可信号
コモン
ピン番号
:4(フロント側)
ピン
番号:12(リア側)
搬出要求出力信号
ピン番号:1(フロント側)
ピン番号
:9(リア側)
搬出要求信号コモン
ピン番号:2(フロント側)
ピン
番号
10(
リア
側)
マウンタ
上流側装置
Figure Signal interface and connected terminals
8-2-1 Specifications of a connection cable
Use one of the following connection cables according to a machine you use.
Table of cables to be used
RX-7/ RX-7R /
RX-6
(Dual Mode)
RX-7 / RX-7R / RX-6,
KE-3020VA
(Single mode / Lane
device)
Inspection machine and
another device
(Dual-Lane device)
RX-8 Single mode 0, 1, 2
0: Joint cable (conventional cable : E9599705A0)
1: Joint cable 1 (Standard attached to RX-7 / RX-7R options : EZ184657712)
2: Joint cable 2 (optional : EZ184660811)
8-3 Data interface
A LAN (10/100/1000BASE-T) is provided as the JaNets interface.
You can use a CD-ROM to be connected via the USB as the interface of the main unit.
(Two USB connecters are located on the front side.)
8-4 Utility connection
8-4-1 Piping joint
A Nittoh Kohki Hi Cupla (20PM) is located on the air supply port of the main unit.
A one-touch coupler is supplied with the machine at the factory.
Nittoh Kohki Co., Ltd. Hi Cupla Model: 20SH
Downstream device Mounter Upstream device
Board eject request input signal
Pin number: 1 (front side)
Pin number: 9 (rear side)
Board eject request signal
common
Pin number: 2 (front side)
Pin number: 10 (rear side)
Board eject permission
output signal
Pin number: 3 (front side)
Pin number: 11 (rear side)
Board eject permission
signal common
Pin number: 4 (front side)
Pin number: 12 (rear side)
Board eject request output signal
Pin number: 1 (front side)
Pin number: 9 (rear side)
Board eject request signal common
Pin number: 2 (front side)
Pin number: 10 (rear side)
Board eject permission input signal
Pin number: 3 (front side)
Pin number: 11 (rear side)
Board eject permission signal common
Pin number: 4 (front side)
Pin number: 12 (rear side)
31
9. Safety Specifications
9-1 Standard specifications
Emergency stop
The machine is equipped with one emergency stop button on the front side.
Depressing the emergency stop button immediately stops each axis to cut off the power supply for
driving the servomotors.
Safety cover
The machine is equipped with a cover on the front side. The cover open switch detects the cover
opening or closing state. When you open the cover, it interrupts transmission of power to each axis,
and the machine is put into the emergency stop state.
Moreover, each feeder trolley is equipped with a safety switch, and when the trolley is moved down,
transmission of power to each axis is interrupted, and the machine is put into the emergency stop
state. (Any operation of the conveyor belt, the support table or the component supply device is not
affected with this emergency stop.)
Even though you press the Start switch while the cover is opened or while the trolley is moved down,
the machine displays the corresponding message without operating any axis.
Interlock specifications
While the cover opens or while a feeder trolley is moved down, the power system including the
XY-axes is turned off.
9-2 Specifications of the CE marking
The machine conforms to the following EC directives:
EC machinery directive 2006/42/EC
EC EMC directive 2014/30/EU
EC RoHS directive 2011/65/EU
Applicable standards
Machinery directives EN IS012100:2010, EN60204-1:2006+Al:2009, EN ISO13849-1:2015
EMC directives EN61000-6-4:2007+A1:2011, EN IEC61000-6-2:2019,
EN61000-4-2:2009,
EN61000-4-3:2006+A1:2008+A2:2010, EN61000-4-4:2012,
EN61000-4-5:2014+A1:2017, EN61000-4-6:2014, EN61000-4-8:2010,
EN61000-4-34:2005+A1: 2009
EC RoHS directive EN IEC63000:2018
9-3 Other laws and regulations
Laser device
HMS: Class II (JIS C6802 Class 2, FDA Class II), EN60825