20121120111955_KY8030_2_Maintenance_Manual_Eng_ver1.pdf - 第23页
Maintenance Manual | 23 1.2. Instrument Maintenance and Repair 1.2.1. X / Y A XIS G REASING Figure 1-1. Y – Axis Grea sing

22 | KY-8030 2
3DSolderPasteInspectionSystem
Version 1.0
KOH YOUNG TECHNOLOGY INC.
Unit Item Check/Maintenance
Maintenance Cycle
Every
Operation
Every
Month
Every
3Month
Every
6Month
Electric
Box
Computer
Computer Location/Connector
check
O
Power
Power connection and cable
check
O
Circuit breaker (MCCB)
functioning check
O
Board
Boards connection/Connector
check
O
Fan
Fan Functioning Check O
Fan Filter check and change O
Cleaning Electric Box Cleaning O
Probe
Camera
Camera connection check O
Camera cable connection
check
O
Lens Cover Cleaning check O
Illumination
Projection Illumination check O
2D Illumination check O
Door
Upper Door
Inter Lock S/W
functioning/Key connection
check
O
Door and magnetic
connection check
O
Lower Door
Main harness panel
connection check
O
Door and magnetic
connection check
O
Misc.
Cover
Cover damage and
deformation check
O
Tow er Lamp Tower Lamp check O
Alarm
Alarm functioning and sound
check
O

Maintenance Manual | 23
1.2. Instrument Maintenance and Repair
1.2.1. X / Y AXIS GREASING
Figure 1-1. Y – Axis Greasing

24 | KY-8030 2
3DSolderPasteInspectionSystem
Version 1.0
KOH YOUNG TECHNOLOGY INC.
Figure 1-2. X – Axis Greasing
1. Cutthepower/theairsupplyandpressemergencyswitch.
2. OpentheFrontDoor/WindowanddisassembleRearCover/RightSideCover.
3. CleanoffremaininggreaseonLMguide&Ballscrews.
4. Putgrease(THK:HighspeedAFAgrease)inthegreasegun.
5. Applyapproximately30ccofgrease to
LM‐BLOCKandscrewnutsmovingX‐YGantry
up/down.
ÚNote:Greasethemevery6months.Regulatethegreasingintervalsdependingontheconditionof
themovingpartsintheX‐YGantryandcolorandstateofthegrease