2-6 AIX-ML T-ID [3] Component Reload Buttons When the component-reloaded step is selected and the [Set] button is pressed, the tray pickup matrix of the selected step is set to "(1, 1)" and the number of remain…

2-5
AIX-MLT-ID
2.2.1 Pickup Tray Matrix
When the [Pickup Tray Matrix] button is pressed in the "COMP. RELD."
window, the "Pickup Tray Matrix" window appears.
[1] [4] [3]
[2]
Fig. B3 "Pickup Tray Matrix" Window
[1] "Magazine" Selection Buttons
These buttons are used to select a magazine to be activated or reloaded
with components.
[2] Magazine Movement Buttons
[Plt Chng Pos] Button :
When pressed, this button moves the
currently selected magazine to the
component supply position.
[Mag Chng Pos] Button :
When pressed, this button moves the
currently selected magazine to the
magazine change position.
0804-004
2.2 Component Reloading

2-6
AIX-MLT-ID
[3] Component Reload Buttons
When the component-reloaded step is selected and the [Set] button is
pressed, the tray pickup matrix of the selected step is set to "(1, 1)" and
the number of remaining components is updated.
Reloaded Step Selection :
The component-reloaded step must be
selected.
[Overall Attach] Button :
When pressed, this button selects all
steps.
[Set] Button :
When pressed, this button sets the
component reloading condition with the
specied value.
Note
As for the steps that are not used in the pattern program, no component reload
button is displayed.
[4] Step Selection Buttons
When a magazine and a step are selected, the "Block Information"
window appears, making it possible to check and change the tray
matrices.
[5]
[6]
[7]
Fig. B4 "Block Information" Window
[5] "Block Information" Sheet
Shown is the block information.
0804-004
2.2 Component Reloading

2-7
AIX-MLT-ID
[6] Tray Pickup Matrix Setting Buttons
Shown is the tray pickup matrix data.
When the [Edit] button is pressed, an input window opens, making it
possible to set the tray pickup matrix data.
Note
As for the blocks that are not used in the pattern program, no tray pickup
matrix setting button is displayed.
[7] [Return] and [Set] Buttons
[Set] Button :
When pressed, this button sets the edited tray
pickup matrix data and opens the tray pickup
matrix editing window.
[Return] Button :
When pressed, this button cancels the selection
of the tray pickup matrix data and opens the tray
pickup matrix editing window.
0705-003
2.2 Component Reloading