2-34 AIX-ML T-ID 0806-001 3.4 T eaching Operation 3.4.3 "T each Pick-Up Pos" Window This window can be used to perform a teaching operation to determine the feeder (B) offset for the tray components. When the […

2-33
AIX-MLT-ID
(6) Move the object pickup position of Tray #3 for the manual
alignment operation with the image movement buttons until it is
located at the center of the crosshair.
(7) Press the
button in the recognition window to determine the
position.
The recognition window closes and the "T
each Standard Tray Pos"
window resumes.
(8) The results of the teaching operation appear in the tex
t boxes
entitled "Adj" in the "Teach Standard Tray Pos" window.
(9)
Whenthe[End]buttonispressed,the"ConrmationtoSaving"
dialog box opens, asking you to answer if the data should be saved
or not.
Whenthe[Y
es]buttonispressed,thedataisreectedonthe
component library data is written over the previous one.
Pressing the [No] button cancels the data save operation.
0806-001
3.4 Teaching Operation

2-34
AIX-MLT-ID
0806-001
3.4 Teaching Operation
3.4.3 "Teach Pick-Up Pos" Window
This window can be used to perform a teaching operation to determine the
feeder (B) offset for the tray components.
When the [Teach Pick-Up Pos] button is pressed in the "Pick-Up Location"
window, the "Teach Pick-Up Pos" window appears.
[5]
[1]
[4]
[6]
[3][7] [2]
Fig. B27 "Teach Pick-Up Pos" Window
[1] Head Selection Buttons
Each head in the graphic image of the machine is provided with a
button function.
The installed multi-layer tray feeders are displayed, making it possible
for the operator to select one of the feeders.
[2]
Feeder (B) Offset
Displayed are the current values that indicate the pickup position. After
a teaching operation is performed, the results appear in the text boxes
entitled "Adj".
Cur :
Values before Teaching Operation
Adj :
Results of Teaching Operation

2-35
AIX-MLT-ID
0806-001
3.4 Teaching Operation
[3] Operation Buttons
[Teach Pick-Up Pos] Button
When pressed, this button performs a teaching operation on the pickup
position.
When the [START] button on the operation panel is pressed in 10
seconds after this button, the "Manual Alignment Operation Guide"
window appears.
[All Beam Heads Zero] Button
When pressed, this button zeroes the stage on which a teaching
operation is performed.
[Beam XY zero move] Button
When pressed, this button returns the beams to their X and Y origins.
[4]
[Tray Unit Adj.] Button
When pressed, this button opens the "TRAY UNIT" window.
Fig. B28 "TRAY UNIT" Window
·
Procedure for T
eaching Operation
(1) Select the feeder base for which the teaching operation should be
performed.
(2) Press the [Fdr No.] button and enter the required feed
er No.
(3) Press the [All Beam Heads Zero] button to zero the stage on the
teaching side.