Command Groups T able 2-41: T rigger Commands (cont.) Command Description TRIGger:B:EDGE:SLOpe This command speci fi es the B edge trigger slope TRIGger:B:EDGE:SOUrce This command speci fi es the B edge trigger source TRIG…

Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:TIMEOut:T IMe When triggering using the TIMEOut trigger type, this command specifies the
timeout time, in seconds. The default and minimum is 4.0E-9 seconds and the
maximum is 8.0 seconds. The resolution is 800.0E-12 which means that the
increments of time specified is 800 picoseconds.
TRIGger:A:TYPe This command sets the type of A trigger (edge, logic, pulse, bus or video). If
you set the trigger type to LOGIc, you also need to set the logic trigger class
(logic or setup/hold) using the command TRIGger:A:LOGIc:CLAss.Ifyouset
the trigger type to PULSe, you also need to set the pulse trigger class (runt,
width, transition or timeout), using the command TRIGger:A:PULse:C LAss.
TRIGger:A{:TRANsition|:RISEFall}?
Returns the delta time, polarity, and both upper and lower threshold limits
for the transition time trigger
TRIGger:A{:TRANsition|:RISEFall}:DELTatime This command specifies the delta time used in calculating the transition value
TRIGger:A{:TRANsition|:RISEFall}:POLarity This comm and specifies the polarity for the A pulse transition trigger
TRIGger:A{:TRANsition|:RISEFall}:SOUrce This command specifies the source for transition trigger.
TRIGger:A{:TRANsition|:RISEFall}:WHEn This command specifies the relationship of delta time to transitioning signal
TRIGger:A:TYPe This command specifies the type of A trigger. Once you have set the trigger
type, you may also need to identify the associated trigger class. For details on
selecting Logic and Pulse trigger classes, see TRIGger:A:LOGIc:CLAss and
TRIGger:A:PULse:CLAss respectively.
TRIGger:A:UPPerthreshold:CH<x> Sets the upper threshold for the channel selected
TRIGger:A:UPPerthreshold:RF This command specifies the upper threshold when the internal RF power level
is used as a trigger. This is only applicable to the RUNT trigger type.
TRIGger:A:VIDeo? Returns the video parameters for the A trigger
TRIGger:A:VIDeo:CU STom{:FORMat|:TYP e} This command sets the video trigger format (either interlaced or progressive)
to use for triggering on video signals.
TRIGger:A:VIDeo:CUSTom:LINEPeriod This command sets the l ine period for the standard under test.
TRIGger:A:VIDeo:CU S Tom:SYNCInterval This command sets the sync interval for the standard under test to use for
triggering on video signals. This is only required for BiLevel Custom.
TRIGger:A:VIDeo:HOLD off:FIELD This command sets the video trigger holdoff, in terms of video fields, to u se for
triggering on video signals.
TRIGger:A:VIDeo:LINE This command sets the video line number to use for triggering on video signals.
TRIGger:A:VIDeo:POLarity This command sets the polarity to use for triggering on video signals.
TRIGger:A:VIDeo:S OU rce This command sets the source channel to use for triggering on video signals
(CH1–4).
TRIGger:A:VIDeo:STANdard This command sets the standard to use for triggering on v ideo signals.
TRIGger:A:VIDeo{:SYNC |:FIELD } This command sets the video field to use for triggering on video signals (odd,
even, all fields, all lines, numeric).
TRIGger:B Sets the B trigger level to 50% or returns the B trigger parameters
TRIGger:B:BY This command specifies B trigger time or event qualifiers
TRIGger:B:EDGE?
Returns B trigger edge type parameters
TRIGger:B:EDG E:COUPling This command specifies the type of B trigger coupling
2-90 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:B:EDGE:SLOpe This command specifies the B edge trigger slope
TRIGger:B:EDGE:SOUrce This command specifies the B edge trigger source
TRIGger:B:EVENTS?
Returns the current B trigger events parameter
TRIGger:B:EVENTS:C OU Nt This command specifies the number of events that must occur before the
B trigger occurs
TRIGger:B:LEVel This command specifies the level for the B trigger
TRIGger:B:LEVel:CH<x> This command specifies the level for the B trigger for a specific channel
TRIGger:B:LEVel:D<x> This command specifies the B trigger level for digital channel <x>
TRIGger:B:LOWerthreshold:CH<x> This command specifies the B trigger lower threshold for the channel selected
TRIGger:B:LOWerthreshold:D<x> Sets or queries the B trigger lower threshold for the digital channel selected
TRIGger:B:STATE Returns the current state of the B trigger
TRIGger:B:TIMe This command specifies the B trigger delay time
TRIGger:B:TYPe This command specifies the type of B trigger
TRIGger:EXTernal? Returns all external trigger-related parameters for the probe connected to the
Aux Input connector.
TRIGger:EXTernal:PRObe This command specifies the attenuation factor value of the probe connected
to the A ux Input connector.
TRIGger:EXTernal:YUNIts? Returns the external trigger vertical (Y) units value
TRIGger:FREQuency? Returns the trigger frequency in hertz, if available
TRIGger:STATE? Returns the current state of the triggering system
Vertical Command Group
Use the commands in the Vertical Command Group to control the vertical setupof
all live (channel) waveforms for acquisition and display of channel, reference,
and math waveforms.
Use the command CH<x>:YUNits to set the vertical units for each channel. The
vertical units affect the “Probe Type” that is shown in the “Probe Setup” menu:
Setting CH<x>:YUNits to “V” causes the probe type to be displayed as
“Voltage”.
When CH1:AMSVIAVOLTs:ENAble is set to OFF, setting CH<x>:YUNits to
“A” causes the probe type to be displayed as “Current”.
Setting CH<x>:YUNits to anything else causes the probe type not to be
displayed (neither “Voltage” nor “Current” are highlighted).
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-91

Command Groups
Table 2-42: Ver
tical Commands
Command Description
AUXin?
Returns Aux In
put connector parameters
AUXin:PRObe Returns all information concerning the probe attached to Aux Input connector
AUXin:PRObe:AUTOZero Sets the TekVPI probe attached to the Aux Input connector to autozero
AUXin:PRObe:CALibrate:CALIBRATABLe?
This query i
ndicates whether the attached probe is calibratable.
AUXin:PRObe:COMMAND Sets the state of the specified probe control
AUXin:PRObe:DEGAUss Starts a degauss/autozero cycle on a TekVPI current probe attached to the
Aux Input connector
AUXin:PRObe:DEGAUss:STATE? Returns the degauss state of the TekVPI current probe attached to the Aux
Input co
nnector
AUXin:P
RObe:FORCEDRange
This com
mand specifies the range of the TekVPI probe attached to the Aux
Input connector
AUXin:PRObe:GAIN This command specifies the gain factor of the probe that is attached to the
Aux Input connector
AUXin:PRObe:ID:SERnumber? Returns the serial number of the probe that is attached to the Aux Input
conne
ctor
AUXi
n:PRObe:ID:TYPe?
Retu
rns the type of probe that is attached to the Aux Input connector
AUXi
n:PRObe:RESistance?
Retu
rns the resistance of the probe that is attached to the Aux Input connector
AUX
in:PRObe:SIGnal
Thi
s command specifies the input bypass setting on VPI probes that support
input bypass
AUXin:PRObe:UNIts? Returns the units of measure of the probe that is attached to the Aux Input
connector
CH<x>? Returns vertical parameters for the specified channel
CH<x>:AMPSVIAVOLTs:ENA ble This command specifies the state of the amps via volts feature for the specified
c
hannel
C
H<x>:AMPSVIAVOLTs:FACtor
T
his command specifies the amps via volts factor for the specified channel
CH<x>:BANdwidth This command specifies the bandwidth of the specified channel
CH<x>:COUPling This command specifies the coupling setting for the specified channel
CH<x>:DESKew This command specifies the deskew time for the specified channel
CH<x>:INVert This command specifies the invert function for the specified channel
CH<x>:LABel This command specifies the waveform label for channel <x>
CH<x>:OFFSet This command specifi es the channel offset
CH<x>:POSition This command specifies the channel vertical position
CH<x>:PRObe? Returns the gain, resistance, units, and ID of the probe that is attached to
the specified channel
CH<x>:PRObe:AUTOZero Sets the TekV PI probe attached to the specified channel input to autozero
CH<x>:PRObe:CALibrate This command executes a calibration or initialization for the probe attached
to the auxilliary input, if the probe is calibratable.
CH<x>:PRObe:CALibrate:CALIBRATAB Le? This query returns the state of the probe attached to channel 1–4, either 0 if
the probe is not calibratable, or 1 if the probe is calibratable.
2-92 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual