MDO3000 Programmer Manual.pdf - 第625页
Commands Listed in Alphabetical Order NOTE. < fi lename > stands for a fi lename of up to 125 characters, followed by a period (".") and the thr ee-character extension. W aveform fi les should have a .csv ex…

Commands Listed in Alphabetical Order
SAVe:ASSIgn:
TYPe
This command specifies the assignment of the data to be saved when the
front-panel Save button is pressed.
Group
Save and Recall
Syntax
SAVe:ASSIgn:TYPe {IMAGe|WAVEform|SETUp}
SAVe:ASSIgn:TYPe?
Arguments
IMAGe assigns the Save button to save screen images.
WAVEform assigns the Save button to save waveforms.
SETUp assigns the Save button to save setups.
SAVe:EVENTtable:{BUS<x>|B<x>} (No Query Form)
Saves the data from bus<x> to a specified file and location; where x is the bus
number (1-4). 1-3 for the MDO4000C and 1-2 for the MDO3000.
NOTE. External filestructureisasfollows:
E: is the USB memory device plugged into the first USB port o n the front of the
oscilloscope.
F: is the USB memory device plugged into the second USB port on the front of
the oscilloscope.
G: and H: are the USB memory device plugged into the USB ports on the rear o f
the oscilloscope.
I: is the network storage.
However, the MDO3000 only has two ports. E: is on the front and F: is on the rear.
Group
Save and Recall
Syntax
SAVe:EVENTtable:{BUS<x>|B<x>} <file path>
Arguments
<file p ath> is a quoted string that defines the file name and path location
where the event table will be stored.
2-594 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
NOTE. <filename
> stands for a filename of up to 125 characters, followed by a
period (".") and the three-character extension. Waveform files should have a .csv
extension for comma-separated spreadsheet format files.
SAVe:IMAGe (No Query Form)
Saves a capt
ure of the screen image to the specified file. Supported image
formats are PNG, Windows Bitmap, and TIFF. The file format is specified by the
SAVe:IMAGe:FILEFormat command. The SAVe:IMAGe:INKSaver command
determines whether the data is saved in InkSaver mode.
NOTE. The external fi le structure is as follows:
E: is the USB memory device plugged into the first USB port on the front of the
oscilloscope.
F: is the USB memory device plugged into the second USB port on the front of the
oscilloscope. (Not available for MDO3000.)
G: and H: are the USB memory device plugged into the USB ports on the rear of
the oscilloscope. (Not available for MDO3000 models.)
I: is the network storage.
Group
Save and Recall
Syntax
SAVe:IMAGe <file path>
Related Commands
SAVe:ASSIgn:TYPe
Arguments
<file p ath> is a filename, including path, where the image will be saved. If you
do not specify a directory, the oscilloscope will store the file in the current working
directory. File name extensions are not required but are highly recommended.
SAVe:IMAGe:FILEFormat
This command specifies the file format to use for saving screen images.
NOTE. The file format is not automatically determined by the file name extension.
Youneedtochooseafile format with an extension which is consistent with the
selected fi le format.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-595

Commands Listed in Alphabetical Order
Group
Save and Recall
Syntax
SAVe:IMAGe:FILEFormat {PNG|BMP|TIFf}
SAVe:IMAGe:FILEFormat?
Related Commands
SAVe:IMAGe
Arguments
PNG saves the file in Portable Network Graphics format.
BMP saves the file in Microsoft Windows bitmap format.
TIFf saves the file in Tagged Image File Format.
SAVe:IMAGe:INKSaver
This command specifies the current ink saver setting for the SAVe:IMAGe
command. If set to “ON” or “1”, images will be generated using the ink saver
palette. If set to “OFF” or “0”, images will be generated using the standard palette.
Group
Save and Recall
Syntax
SAVe:IMAGe:INKSaver {OFF|ON|0|1}
SAVe:IMAGe:INKSaver?
Related Commands
SAVe:IMAGe
Arguments
OFF or 0 generates images from the Inksaver palette.
ON or 1 generates images using the Standard palette.
SAVe:IMAGe:LAYout
This command specifies the layout to use for saved screen images.
Group
Save and Recall
Syntax
SAVe:IMAGe:LAYout {LANdscape|PORTRait}
SAVe:IMAGe:LAYout?
2-596 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual