Commands Listed in Alphabetical Order SEARCH:SEARC H<x>:TRIGger:A:LOGIc:INPut:REF<x> This command specifies the logic condition of the reference waveform to be used in a logic search. SEARCH<x> is the se…

100%1 / 1158
Commands Listed in Alphabetical Order
NONe specifies n
o clock source.
D0-D15 specifies a digital channel as the clock source.
RF_AMPlitude|RF_FREQuency|RF_PHASe specifyanRFtimedomaintraceas
the clock source. (MDO4000/B/C only.)
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:D<x>
This command specifies the logic condition to be used in a logic search when the
input is a digital channel.
SEARCH<x> is the search number, which is always 1,
and
D<x> is the digital channel number, which can be D0 D16.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:D<x> {HIGH|LOW|X}
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:D<x>?
Arguments
HIGH specifies a high logic level.
LOW specifies a low logic level.
X specifies a “don't care” condition.
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:MATH
This command specifies the logic condition of the math input to be used in a logic
search. <x> is the search number, which is always 1.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:MATH {HIGH|LOW|X}
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:MATH?
Arguments
HIGH specifies a high logic level.
LOW specifies a low logic level.
X specifies a “don't care” condition.
2-722 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:LOGIc:INPut:REF<x>
This command specifies the logic condition of the reference waveform to be
used in a logic search.
SEARCH<x> is the search number, which is always 1, and
REF<x> is the
reference channel number, which can be 1–4.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:REF<x> {HIGH|LOW|X}
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:REF<x>?
Arguments
HIGH specifies a high logic level.
LOW specifies a low logic level.
X specifies a “don't care” condition.
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_AMPlitude
This command specifies the logic criteria to search for when searching using
the RF Amplitude vs. Time trace. This command is used together with
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_AMPlitude to
search for an instance when the waveform goes higher or lower than the specified
threshold. “LOW specifies to only set a mark when the RF_AMPlitude
waveform drops below the logic threshold; likewise, “HIGH
specifies to set a
mark when the waveform goes above the logic threshold. “X” specifies “don’t
care”.
SEARCH<x> is the search number, which is always 1.
Conditions
MDO4000/B/C models only.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_AMPlitude
{HIGH|LOW|X}
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_AMPlitude?
Related Commands
TRIGger:A:LOGIc:INPut:RF
Arguments
HIGH specifies a high logic level.
LOW specifies a low logic level.
X specifies a “don't care” condition.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-723
Commands Listed in Alphabetical Order
Examples
SEARCH:SEARCH
1:TRIGger:A:LOGic:INPut:RF_AMPlitude HIGH
specifies to set a mark when the waveform goes above the logic threshold specified
by SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_AMPlitude.
SEARCH:SEARCH1:TRIGger:A:LOGic:INPut:RF_AMPlitude? might
return HIGH, indicating that the search engine has been set to set a
mark when a waveform goes above the logic threshold specified by
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_AMPlitude.
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_FREQuency
This comm
and specifies the logic criteria to search for when searching using
the RF Frequency vs. Time trace. This command is used together with
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_FREQuency to
search for an instance when the waveform goes higher or lower than the specified
threshold. “LOW” specifies to only set a mark when the RF_FREQuency
waveform drops below the logic threshold; likewise, “HIGH” specifies to seta
mark wh
en the waveform goes above the logic threshold. “X” specifies don’t
care”.
SEARCH<x> is the search number, which is always 1.
Conditions
MDO4000/B/C models only.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_FREQuency
{HIGH|LOW|X}
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:INPut:RF_FREQuency?
Related Commands
TRIGger:A:LOGIc:INPut:RF
Arguments
HIGH specifies a high logic level.
LOW specifies a low logic level.
X specifies a “don't care” condition.
Examples
SEARCH:SEARCH1:TRIGger:A:LOGic:INPut:RF_FREQuency HIGH
specifies to set a mark when the waveform goes above the logic threshold specified
by SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_FREQuency.
SEARCH:SEARCH1:TRIGger:A:LOGic:INPut:RF_FREQuency? might
return HIGH, indicating that the search engine has been set to set a
mark when a waveform goes above the logic threshold specified by
SEARCH:SEARCH<x>:TRIGger:A:LOGIc:THReshold:RF_FREQuency.
2-724 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual