MDO3000 Programmer Manual.pdf - 第727页
Commands Listed in Alphabetical Order Related Commands SEARCH:SEARCH <x>:TRIGger:A:BUS:B<x>:RS232C:CONDition Arguments <NR1> is the length of t he data string in Bytes. SEARCH:SEARCH<x>:TRIGger:A:…

Commands Listed in Alphabetical Order
SEARCH:SEARC
H<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
This command specifies the condition to be used in an RS-232 search. SEARCH< x>
is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4COMP application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3COMP application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
{RXSTArt|RXDATA|RXENDPacket|TXSTArt|TXDATA|TXENDPacket}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition?
Arguments
RXSTArt specifies a search based on the RX Start Bit.
RXDATA specifies a search based on RX Data.
RXENDPacket specifies a search based on the RX End of Packet condition.
TXSTArt specifies a search base on the TX Start Bit.
TXDATA specifies a search based on TX Data.
TXENDPacket specifies a search based on the TX End of Packet condition.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe
This command specifies the length of the data string to be used in an
RS-232 search, if the search condition is set to
RXDATA. SEARCH<x> is the search
number, which is always 1, and
B<x>
Conditions
This command requires a DPO4COMP application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3COMP application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe?
2-696 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Related Commands
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
Arguments
<NR1> is the length of the data string in Bytes.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
This command specifies the data value to be used in an RS-232 search, if the
condition is set to
RXDATA. SEARCH<x> is the search number, which is always
1, and
B<x>
Conditions
This command requires a DPO4COMP application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3COMP application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe
This command specifies the length of the data string to be used for an
RS-232 search if the search condition is set to
TXDATA. SEARCH<x> is the search
number, which is always 1, and
B<x>
Conditions
This command requires a DPO4COMP application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3COMP application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-697

Commands Listed in Alphabetical Order
Arguments
<NR1> is the len
gth of the data string in Bytes.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
This command specifies the data value to be used for an RS-232 search, if the
condition is
set to
RXDATA. SEARCH<x> is the search number, which is always
1, and
B<x>
Conditions
This command requires a DPO4COMP application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3COMP application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:RS232C:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:CONDition
This command specifies the search condition for a SPI search. SEARCH<x> is the
search number, which is always 1, and
B<x>
Conditions
This command requires a DPO4EMBD application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3EMBD application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:CONDition
{SS|STARTofframe|MISO|MOSI|MISOMOSI}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:SPI:CONDition?
Related Commands
BUS:B<x>:SPI:IDLETime,
BUS:B<x>:SPI:FRAMING
2-698 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual