MDO3000 Programmer Manual.pdf - 第52页
Command Groups Ta b l e 2 - 2 0 : C o n fi guration Commands (cont.) Command Description CONFIGuration:BUSW A VEFORMS:LIN? This query returns a boolean value to indicate whether the optional LIN bus triggering and analysi…

Command Groups
Table 2-20: Configuration Commands (cont.)
Command
Description
CONFIGuration:ANALOg:GNDCPLG?
This query returns a boolean value to indicate whether the
instrument supports the ground coupling feature for analog
channels. As this feature is not supported on M SO /DPO4000B
or MDO4000/B/C models, this query always returns 0.
CONFIGuration:ANALOg:MAXBANDWidth? Returns the maximum bandwidth for analog channels.
CONFIGuration:ANALOg:MAXSAMPLERate? This query returns the m aximum sample rate for analog channels.
CONFIGuration:ANALOg:NUMCHANnels? This query returns the number of analog channels.
CONFIGuration:ANALOg:RECLENS? This query returns a list of supported record lengths for analog
channels.
CONFIGuration:ANALOg:VERTINVert?
This query returns a boolean value to indicate whether the
instrument supports the vertical invert feature for analog
channels.
CONFIGuration:APPLications:CUSTOMMask? Indicates whether the Custom Mask test feature is present and
enabled.
CONFIGuration:APPLications:LIMITMask?
This query returns a boolean value to indicate whether the
instrument supports the mask/limit test application feature.
CONFIGuration:APPLications:POWer?
This query returns a boolean value to indicate whether the
optional power application feature is present.
CONFIGuration:APPLications:STANDARDMask? Indicates whether the Standard Mask test feature is present
and enabled.
CONFIGuration:APPLications:VIDPIC? Indicates whether the Video Picture feature is present and
enabled.
CONFIGuration:ARB? Indicates whether or not the arbitrary function generator
hardware is present, and the user-defined arbitrary waveform
generation feature is enabled. Note that this is different than the
CONFIGuration:AFG? query.
CONFIGuration:AUXIN?
This query returns a boolean value to indicate whether the
instrument has an Aux Input connector.
CONFIGuration:BUSWAVEFORMS:ARINC429A?
This query returns a boolean value to indicate whether the
optional ARINC429 bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:AUDIO?
This query returns a boolean value to indicate whether the
optional audio bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:CAN?
This query returns a boolean value to indicate whether the
optional CAN bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:CANFD?
This query returns a boolean value to indicate whether the
optional CAN FD bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:ETHERNET?
This query returns a boolean value to indicate whether the
optional Ethernet triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:FLEXRAY?
This query returns a boolean value to indicate whether the
optional FlexRay bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:I2C?
This query returns a boolean value to indicate whether the
optional I
2
C bus triggering and analysis feature is present.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-21

Command Groups
Table 2-20: Configuration Commands (cont.)
Command
Description
CONFIGuration:BUSWAVEFORMS:LIN?
This query returns a boolean value to indicate whether the
optional LIN bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:MIL1553B?
This query returns a boolean value to indicate whether the
optional MIL-S TD-1553 bus triggering and analysis feature is
present.
CONFIGuration:BUSWAVEFORMS:NUMBUS? This query returns the number of bus waveforms.
CONFIGuration:BUSWAVEFORMS:PA Rallel?
This query returns a boolean value to indicate whether the
parallel bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:RS232C?
This query returns a boolean value to indicate whether the
optional RS232 bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:SPI?
This query returns a boolean value to indicate whether the
optional SPI bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:USB? This query returns a boolean value to indicate whether the USB
bus triggering and analysis feature is present.
CONFIGuration:BUSWAVEFORMS:USB:HS?
This query returns a boolean value to indicate whether the
high-speed USB bus triggering and analysis feature is present.
CONFIGuration:DIGITAl:MAGnivu?
This query returns a boolean value to indicate whether the
instrument supports the MagniVu feature for digital channels. If
there are no digital channels, the value returned is 0.
CONFIGuration:DIGITAl:MAXSAMPLERate? This query returns the maximum sample rate for digital channels,
in samples per second.
CONFIGuration:DIGITAl:NUMCHANnels? This query returns the number of digital channels.
CONFIGuration:DVM?
Indicates whether the Digital Voltmeter hardware is present. and
the DVM feature is enabled.
CONFIGuration:EXTVIDEO?
This query returns a boolean value to indicate whether the
optional extended video trigger features are present.
CONFIGuration:HISTOGRAM?
This query returns a boolean value to indicate whether the
waveform histogram feature is present.
CONFIGuration:NETWORKDRIVES?
This query returns a boolean value to indicate whether network
drives are present.
CONFIGuration:NUMMEAS? This query returns the number of periodic measurements.
CONFIGuration:REFS:NUMREFS? This query returns the number of reference waveforms.
CONFIGuration:RF:ADVTRIG?
This query returns a boolean value to indicate whether the
advanced RF trigger and analysis feature is present.
CONFIGuration:RF:BANDWidth? This query returns the maximum bandwidth, in hertz, for RF
channels. If there are no RF channels, the value returned is 0.
CONFIGuration:RF:MAXBANDWidth? Returns the maximum bandwidth, in hertz, for RF channels.
CONFIGuration:RF:NUMCHANnels? This query returns the number of RF channels present.
CONFIGuration:ROSC?
This query returns a boolean value to indicate whether the
instrument has an external reference oscillator ( RO SC) input.
2-22 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Cursor Comman
dGroup
Use the commands in the Cursor Command Group to control the cursor display
and readout. You can use these commands to control the setups for cursor 1 and
cursor 2, suc
h as cursor position.
You can also use the commands to select one of the following cursor functions:
Off. Turns off the display of all cursors.
Waveform Cursors. Consists of two cursors. Waveform cursors enable you
to conveniently measure waveform amplitude and time.
Screen Cursors. Consists of two pairs of independent horizontal and vertical
cursors. You can use these cursors to indicate an arbitrary position within
the waveform display area.
Table 2-
21: Cursor Commands
Command
Descrip
tion
CURSor?
Return
s cursor settings
CURSor:DDT? Returns the cursor deltaY/deltaT (dY/dT) readout
CURSor:FUNCtion This command specifies the cursor type
CURSor:HBArs?
Retu
rns hbar cursor settings
CURSor:HBArs:DELTa? Returns hbars cursors vertical difference
CURSor:HBArs:POSITION<x> This command specifies the hbar cursor<x> v ertical position
CURSor:HBArs:UNIts
Ret
urns hbar cursor units
CURSor:HBArs:USE Sets the horizontal bar cursor measurement scale, for use with ratio c ursors
CURSor:MODe This command specifies whether cursors move in unison or separately
CURSor:SOUrce This command specifi es the cursor source, which can be one of channels 1–4, reference
waveforms 1–4, math waveform, bus 1–4, digital channels 0– 15 (MSO/MDO4000 models
and MDO3000 and MDO4000C models w ith option M DO 3MSO or MDO4MSO installed),
the RF time domain traces, (MDO4000/B models) or AUTO.
CURSor:VBArs? This command specifies the position of vertical bar cursors
CURSor:VBArs:ALTERNATE<x>? Returns the alternate r eadout for the waveform (Vbar) cursors
CURSor:VBArs:DELTa? Returns the horizontal difference between vbar cursors
CURSor:VBArs:HPOS<x>? Returns the vertical value of the specified vertical bar tick
CURSor:VBArs:POSITION<x> This command specifies the vbar cursor<x> horizontal position
CURSor:VBArs:UNIts This command specifies the horizontal units for vbar cursors
CURSor:VBArs:USE Sets the vertical bar cursor measurement scale
CURSor:VBArs:VDELTa? Returns the vertical difference between the two vertical bar cursor ticks
CURSor:XY:POLar:RADIUS:DELta? Returns the difference between the cursors X radius and the cursor Y radius
CURSor:XY:POLar:RADIUS:
POSITION<x>?
Returns the polar radius of the specified cursor
CURSor:XY:POLar:RADIUS:UNIts?
Returns the polar radius units
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-23