MDO3000 Programmer Manual.pdf - 第836页
Commands Listed in A lphabetical Order Syntax TRIGger:A:BUS :B<x>:ETHERnet:T CPHeader:ACKnum :VALue <QStr ing> TRIGger:A:BUS :B<x>:ETHERnet:T CPHeader:ACKnum :VALue? Related Commands TRIGger:A:BUS:B<…

Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:ETHERnet:QUALifier
This command specifies the qualifier to be used when the Ethernet trigger
condition is set to
MACLENgth or DATa . Normally, the Ethernet qualifier is set to
“Equal to”.
B
<x>
is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:QUALifier
{LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual
|INrange|OUTrange}
TRIGger:A:BUS:B<x>:ETHERnet:QUALifier?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:VALue
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
TRIGger:A:BUS:B<x>:ETHERnet:DATa:VALue
TRIGger:A:BUS:B<x>:ETHERnet:DATa:HIVALue
Examples
TRIGger:A:BUS:B1:ETHERnet:QUALifier LESSthan sets the MACLENgth
or DATa
qualifier to less than.
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32–bit acknowledgement number that is to be used in the trigger (along with
the destination and source port addresses and the sequence number). The default
is all X’s (don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-805

Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:ETHERnet:TCPHeader:ACKnum:VALue <QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
Arguments
QString is a quoted string of up to 32 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:ACKnum:VALue
“XXXXXXXXXXXXXXXXXXXX00001000”
sets the acknowledgement number to
be used in the trigger to hexadecimal XXXXXX08.
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
When the Ethernet trigger condition is set TCPHeader, this command specifies
the 16–bit destination port address value that is to be used in the trigger (along
with the acknowledgement value, source port address and the sequence number).
The default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
Arguments
QString is a quoted string of up to 16 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
2-806 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Examples
TRIGger:A:BUS
:B1:ETHERnet:TCPHeader:DESTinationport:VALue
“XXXXXXXX00100010”
would set the destination port address value that is to be
used in the trigger to hexadecimal XX22.
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:DESTinationport:VALue?
might return “XXXXXXXXXXXXXXXX”.
TRIGger:A:
BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32–bit sequence number that is to be used in the trigger (along with the
destinat
ion and source port addresses and the acknowledgement value). The
default is all X’s (don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue <QString>
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SEQnum:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:ACKnum:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:SOUrceport:VALue
TRIGger:A:BUS:B<x>:ETHERnet:TCPHeader:DESTinationport:VALue
Arguments
QString is a quoted string of up to 32 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SEQnum:VALue
“XXXXXXXXXXXXXXXXXXXX000100010001”
would set the sequence number
that is to be used in the trigger to hexadecimal XXXXX111.
TRIGger:A:BUS:B1:ETHERnet:TCPHeader:SEQnum:VALue? might return
"XXXXXXXXXXXXXXXXXXXXXX0010010100" .
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-807