Installation Manual SIPLACE SWS Software 2.0 Edition 10/2013 62  T o prepare the USB stick for rem oval, enter th e following: sync 2 2 Fig. 8 Entry of sync 2.2 Inst alling the Operating System 2 2  St a r t t h e P C …

100%1 / 106
Installation Manual SIPLACE SWS Software 2.0
Edition 10/2013
61
To store the wafer feeder SW packages on the USB stick, enter the following:
tar -cvzf /media/usbdisk0/wfBackup.tgz ./wf 2
2
Fig. 5 Entry of tar -cvzf /media/usbdisk0/wfBackup.tgz ./wf
– After the process has been executed, the following will appear on your screen:
2
Fig. 6 Screen after process execution
To test whether the backup was generated, enter the following:
ls -l /media/usbdisk0/wfBackup.tgz 2
2
Fig. 7 Entry of ls -l /media/usbdisk/wfBackup.tgz
Installation Manual SIPLACE SWS Software 2.0
Edition 10/2013
62
To prepare the USB stick for removal, enter the following: sync
2
2
Fig. 8 Entry of sync
2.2 Installing the Operating System
2
2
Start the PC.
Insert the CD.
2
PLEASE NOTE
You can choose between two options for the installation.
Use the arrow keys on your keyboard to select the required option.
PLEASE NOTE
To achieve the required effect, confirm each entry with Enter.
WARNING
Perform a backup of the installed version first
If you are updating an existing system installation, you need to perform a backup of the
installed version first (see Backup of Installed Versionon page 59).
If you do not, you will lost the production data, calibration data and the licenses!
Installation Manual SIPLACE SWS Software 2.0
Edition 10/2013
63
2
Fig. 9 Start window
Enter the following: 2
Confirm with Enter.
2
Fig. 10 Remove the udev network interface connections
Confirm YES with Enter.