6 Pressure control valve (PRV)
6.3 Replacing the exhaust tube
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 59
6.3 Replacing the exhaust tube
Parts
Silicone hose (Di 8, Da 12, conductive, 1m) [03006727Sxx] (replaces: [03095873‑xx])
Overview
Fig.92: Exhaust air hose on the SIPLACE C&P20P
Exhaust air hose on the SIPLACE C&P20P
Length: 355mm
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
Removal
Fig.93: Exhaust air hose
Open the hose clamp(1).
Unplug the exhaust air hose from the pressure
control valve (2).
Installation
Cut the new hose to a length of 355mm.
Follow the removal instructions in reverse order for further installation.
6 Pressure control valve (PRV)
6.4 Calibrating the digital PRV
60 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
6.4 Calibrating the digital PRV
The digital PRV is part of the placement head and generates the vacuum and the blast air for the
pickup and placement process. The zero point calibration of the digital PRV must be performed on
initial startup by the customer and then checked again after replacement of the digital PRV or the
placement head and recalibrated if necessary.
The zero point calibration is used to set the motor in the digital PRV into a neutral or central posi-
tion so that there is no vacuum or air blast at the nozzle.
6.4.1 Zero point calibration of pressure control valve
NOTICE
From SW706 this function is performed automatically (automatic calibration menu).
Fig.94: Set pressure to zero (SW710, example of SIPLACE
CPP)
Switch over to operator level SIPLACE (cus-
tomer).
Click the
button.
Click the
button.
Select the placement head.
Click the
button.
Go to the Specialized tab.
Click on the Zero pressure adjustment button.
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 61
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
NOTICE
Description example
The replacement of the holding circuit (venturi mode) and aperture ring (vacuum pump
mode) is identical. The following section describes the replacement, using the example of
the aperture ring. Any relevant differences will be mentioned explicitly.
Parts
Holding circuit vacuum unit [03005123Sxx]
or
Aperture ring assembly for SIPLACE C&P20P [03116883Sxx] (replaces:[03108716‑xx])
O-ring, if needed:
Vacuum mode (aperture ring): O-ring 40x1.5 [03006234-xx]
Compressed air mode (holding circuit): O-ring 50x1.5 [03046689-xx]