00197490-03_SM_CP20-P-M2_EN保养维护.pdf - 第64页

7 Holding circuit, aperture ring and silencer 7.1 Replacing the holding circuit/reflecting ring 64 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 Torques in vacuum pump operation Fig.97: Cover and…

100%1 / 88
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 63
Fig.96: Holding circuit
1 Holding circuit
(Holding circuit vacuum unit
[03005123Sxx])
2 O-Ring [03046689‑xx]
3 Sealing disc [03005120-xx] 4 Pins
5 Silencer
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
64 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Torques in vacuum pump operation
Fig.97: Cover and aperture ring
1 Cover
Fastening screw M3x14 (Allen key2.5)
Torque: hand-tight
2 Aperture ring
Three fastening screws M3x10
Torque: 1.3Nm
Torques in venturi operation
Silencer
Special screw M3 (SW10)
Torque: hand-tight
Holding circuit
Three fastening screws M3x10 (Allen
key2.5)
Torque: 0.25Nm
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
Fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Safety instructions for the component sensor" [}6]
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 65
Removal
Fig.98: Dismantling the cover
Remove the screw fastening the cover(1) and
then take the cover off.
Fig.99: Screws fastening the aperture ring
Remove the three screws(1) fastening the aper-
ture ring.
Fig.100: Removing the aperture ring
Carefully lever the aperture ring off the locating
pins. Make sure that the O-ring is not damaged.