9 Intermediate distributor
9.1 Replacing the intermediate distributor board
78 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Removal
Fig.120: Pulling the cover off
► Pull the cover(1) off the intermediate distributor.
The cover is fixed by four press studs on the stay
bolts.
NOTICE!
Older heads may not have this cover yet.
.
Fig.121: Dismantling the intermediate distributor board
► Unplug all electrical connections. Mark their posi-
tions to make clear assignment easier later on.
Take particular care not to confuse the two board
connectors(1).
► Remove the four screws fastening the intermedi-
ate distributor and then take off the intermediate
distributor.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
NOTICE
Installation instructions
Transfer the machine data to the EPROM!
► Transfer the machine data from the station to the intermediate distributor. For more in-
formation about this read section 11.3 "Transferring the head specific data (from
SW701)" [}86].

9 Intermediate distributor
9.1 Replacing the intermediate distributor board
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 79
9.1.1 Intermediate distributor board for SIPLACE C&P20P [03110751-xx]
Fig.122: Intermediate distributor board for SIPLACE C&P20P
Connector
X1,X
2
Flat ribbon cable to the head adapter X3 Power supply for star motor
X8 Power supply for Z axis X15 Valve for return unit
X16 CAN bus X16b CAN bus
X17 Z axis light barrier down X19 Board for holding circuit vacuum sensor
X20 Power supply for ED distributor X21 Diagnosis connector
X22 Incremental star X23 Incremental Z axis
X24 Fan X25 Digital pressure control valve
X26 Component sensor
LEDs
H1 Fan Yellow
H2 Fan error Red
H5 +5 V Green
H6 +15 V Green
H8 +24 V Green
H9 Error 24 V DP Red
H11 24 V DP ON Yellow
H12 Return cylinder ON Yellow
H13 Status of pressure control valve Yellow
DIP switches
S1 DP Power ON 1-4 OFF
S1 Z down test 2-3 OFF

9 Intermediate distributor
9.1 Replacing the intermediate distributor board