00197490-03_SM_CP20-P-M2_EN保养维护.pdf - 第61页

7 Holding circuit, aperture ring and silencer 7.1 Replacing the holding circuit/reflecting ring Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 61 7 Holding circuit, aperture ring and silencer 7.1 R…

100%1 / 88
6 Pressure control valve (PRV)
6.4 Calibrating the digital PRV
60 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
6.4 Calibrating the digital PRV
The digital PRV is part of the placement head and generates the vacuum and the blast air for the
pickup and placement process. The zero point calibration of the digital PRV must be performed on
initial startup by the customer and then checked again after replacement of the digital PRV or the
placement head and recalibrated if necessary.
The zero point calibration is used to set the motor in the digital PRV into a neutral or central posi-
tion so that there is no vacuum or air blast at the nozzle.
6.4.1 Zero point calibration of pressure control valve
NOTICE
From SW706 this function is performed automatically (automatic calibration menu).
Fig.94: Set pressure to zero (SW710, example of SIPLACE
CPP)
Switch over to operator level SIPLACE (cus-
tomer).
Click the
button.
Click the
button.
Select the placement head.
Click the
button.
Go to the Specialized tab.
Click on the Zero pressure adjustment button.
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018 61
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
NOTICE
Description example
The replacement of the holding circuit (venturi mode) and aperture ring (vacuum pump
mode) is identical. The following section describes the replacement, using the example of
the aperture ring. Any relevant differences will be mentioned explicitly.
Parts
Holding circuit vacuum unit [03005123Sxx]
or
Aperture ring assembly for SIPLACE C&P20P [03116883Sxx] (replaces:[03108716‑xx])
O-ring, if needed:
Vacuum mode (aperture ring): O-ring 40x1.5 [03006234-xx]
Compressed air mode (holding circuit): O-ring 50x1.5 [03046689-xx]
7 Holding circuit, aperture ring and silencer
7.1 Replacing the holding circuit/reflecting ring
62 Service Manual SIPLACE SpeedStar (C&P20 P / C&P20 M2) 03/2018
Overview
Fig.95: Aperture ring
1 Aperture ring, prefitted for SIPLACE
C&P20P [03116952‑xx])
2 O-ring [03006234-xx]
3 Sealing disc for SIPLACE C&P20P
[03105638-xx]
4 Pins
The pin is located at segment 16
5 Groove – this groove shows the position
of the pin (4) for easier installation.
6 Cover assembly for SIPLACE C&P20P
[03116882‑xx]
Not shown: sealing gasket U - M4 (for