00193897-0302_AI_MTC2+BE_DE+EN.pdf - 第137页

Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series Edition 07/2009 135 2.13 Using the MTC with the CPP placement head : Read the "Head Reconfigur ation CPP" assemb ly instructions,…

100%1 / 146
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
134
: Check for horizontal alignment on the MTC with a spirit level.
2
Fig. 2.12.2 Top view: MTC alignment
2
: Secure the MTC in the machine.
2
2
2
2
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
135
2.13 Using the MTC with the CPP placement head
: Read the "Head Reconfiguration CPP" assembly instructions, if necessary (item no.:
00196428-xx).
2
With the MTC, the placement head must only be fitted in the top position. The installation height
is monitored during the head reference run.
In software version 702, the CPP head is not appro
ved for a 2-gantry placement area with
MTC. In this case there is no nozzle changer available at the location with MTC.
Crash risk: Wh
en the CPP head is used with the MTC, the travel range must also be re-
stricted. You should therefore fit 2x the extens
ion for the Y axis stop (item no.: 03075963-01
"Adaptation, Y axis stop, MTC“). These are included in the package as a precautionary mea-
sure.
Standard stop
Stop withMTC
Assembly instructions MTC2 and Component docking unit on SIPLACE HF and X-series
Edition 07/2009
136
Crash risk: When the CPP head is used with the MTC, the "notched base“ positioning aid on
the pull-out frame of the MTC must also be replaced. You should therefore fit 2 x item no.:
03010773-02 "Notched base“ (height: 103 mm). These are included in the package.
A pull-out frame with the FS04 does not require further conversion.
MTC notched
base (standard)
2
2
When the CPP head is used with the MTC, the crash light barriers on the MTC's feed axis must
be fitted in the bottom position. Read the "MTC2 on component trolley docking unit X-S" as-
sembly instructions (item no. 00194725-xx).
If the CPP is in the high position in conjunction with the MTC
, the lowest pick-up height is 1.5
mm from the top edge of the PCB when the shortest nozzle (9 mm) is used. Interference edges
on the trays should also be taken into account.
2
2
2
2