ACT with SSW 6xx / User Manual 07/2017 Edition 49 Figure 4-25: Dialog box operating mode switchover to SIPLACE Pr o at the station (example SIPLACE D1) ► Press the START button on t he machine. The reference run is ex ec…

100%1 / 132
ACT with SSW 6xx / User Manual 07/2017 Edition
48
Figure 4-23: Dialog box: Access level (example SIPLACE D1)
Enable the Servicetechniker (Service) access level and confirm your entry with OK.
If a password has been defined, a dialog box for entering the password opens.
Enter the password and confirm with OK.
Select the Optionen - Betriebsart...(Options Control mode...) menu items.
Figure 4-24: Basic view of user interface for SC program (example SIPLACE D1)
The Betriebsart (Control mode) dialog box opens.
Select SIPLACE Pro and confirm the setting with OK.
ACT with SSW 6xx / User Manual 07/2017 Edition
49
Figure 4-25: Dialog box operating mode switchover to SIPLACE Pro at the station (example SIPLACE D1)
Press the START button on the machine.
The reference run is executed.
Send the recipe / job to the station with the relevant setup and the ACT placement program.
From the Optionen (Options) menu, select Modus ACT (ACT mode).
The ACT dialog box opens and the machine will automatically switch to Stand Alone mode.
Figure 4-26: Basic view of user interface for SC program (example SIPLACE D1)
After setting Modus ACT (ACT mode) an icon is displayed for ACT.
ACT with SSW 6xx / User Manual 07/2017 Edition
50
Figure 4-27: Dialog box after ACT mode has been set. Display: ACT icon
The Leiterplatteneingabe (Enter PCB) dialog box opens (Figure 4-28):
Select the ACT board.
Figure 4-28: Dialog box: Enter PCB (example SIPLACE D1)
The Leiterplatteneingabe (Enter PCB) dialog box opens (Figure 4-29):
Select the ACT board.
Select the conveyor lane.
Confirm your entry with OK.