ACT - Accuracy Check Tool mit SSW 6xx User Manual 2017.pdf - 第73页
ACT with SSW 6xx / User Manual 07/2017 Edition 9 2.2.1 Options / Spare Parts Item descriptio n Item number Quantity Glass component CC02 - 005 (single ) 00338002 - 01 Glass component (single) Glass component C C07 - 500 …

ACT with SSW 6xx / User Manual 07/2017 Edition
8
2 Prerequisites and Overview of Parts
2.1 Software Requirements
Machine types SIPLACE Pro SIPLACE with SSW 6xx
Additional
software
Importing tables and boards *.sipro
files.
See section 3.2.
Setup depending of version
required.
See section3.2.
Table 2-1: Software requirements
*)
Recommendation: station software 605.03 or higher, with SIPLACE Pro from 11.1.
2.2 Contents "Accuracy Test Device ACT" (Item No. 03068036-01)
Item description Item number Quantity
ACT glass plate with protective lid and
calibration certificate
03056448-01 1 x
Glass components CC02-05, 60 X in
ACT waffle pack tray
03072236-01 1 tray magazine with 60 CC02-
05 components
X-table holder 03069882-01 1 x
S-table holder 03059289-01 1 x
Ceramic components (Cerampads) on
tapes
003539505-02 4 reels with 5,000 components
each (= 20,000)
ACT intervention guard, complete 03073250- 01 1 x
Adhesive foil, cut to size 03071883-01 20 x
CD with user manual, placement
programs, installation file
00196351-03 1 x
Vacuum nozzle 00334547-01 1 x
Case 03072228-01 1 x
Table 2-2: Contents "Accuracy Test Device ACT"
NOTICE
The measuring plate and the special components have been specially designed for the
ACT. The measuring plate has global fiducials for PCB position recognition, fiducials for
component position measurement and a grid array, dot matrix (see Figure 1-2), defined
as inkspot in SIPLACE Pro.
In each glass component, 3 of 4 fiducials are integrated for measuring the component
position.
The special components used depend on the head or camera type fitted (see section
4.1).

ACT with SSW 6xx / User Manual 07/2017 Edition
9
2.2.1 Options / Spare Parts
Item description Item number Quantity
Glass component CC02-005 (single) 00338002-01 Glass component (single)
Glass component CC07-500 (single) 00338000-02 Optional glass component
(single)
1)
Cerampads 2x2 mm in blister tape (for
use in dust-free rooms)
03116117-01 Reel with 2,500 components
Base ACT magazine, complete 03069924-01 Empty magazine (tray) without
cover
Cover for ACT magazine, complete 03069888-01 Cover for ACT magazine (tray)
Cover for glass plate, complete 03056782-01 Cover for glass plate
(Calibration Board)
Light plate 03056307-01 Plate on the underside of the
glass plate
Knurled screw DIN 464 M4 x 16 03031104-01 For closing the glass plate
Knurled screw DIN 464 M4 x 12 03031103-01 For closing the magazine (tray)
Table 2-3: Options / Spare parts
NOTICE
1)
Optional glass components CC07-500
The optional CC07-500 glass components, item no. [00338000-02] were offered as
option for measuring the SST25 (FC camera) up to station software version 707.1.
As of station software version 707.1 and SIPLACE Pro 11.x, this component is not
supported anymore.
Instead, a component description CC02-05_FC is available in SIPLACE Pro as of
version 11.x.
Generally, the following applies and thus also for the 6xx station software:
As of version 11.x, the CC07-
500 component is not contained in the SIPLACE Pro import
data anymore. If the description of this component is still required, it can be requested
via the ASM SIPLACE Hotline and imported separately as * sipro file.

ACT with SSW 6xx / User Manual 07/2017 Edition
10
2.2.2 Individual Components in the ACT Set
Measuring plate (glass plate) in metal frame (Figure 2-1 and Figure 2-2):
The glass components and the measuring plate are kept in a storage case.
Figure 2-1: Storage case for measuring plate Figure 2-2: Storage case for glass components
The glass components used for ACT are placed in the milled divisions in the waffle pack tray
(Figure 2-3).
Figure 2-3: Waffle pack tray for glass components
Key:
(1) Waffle pack tray
(2) Waffle pack tray carrier
(3) Glass components