ACT - Accuracy Check Tool mit SSW 6xx User Manual 2017.pdf - 第91页
ACT with SSW 6xx / User Manual 07/2017 Edition 27 Figure 3 - 26 displays the t ables in the ACT fol der: You can also see a waff le pack tray with 16x4 component ro ws (example C C02 - 05 glass components). 1) 2) Figure …

ACT with SSW 6xx / User Manual 07/2017 Edition
26
► Activate the Overwrite Vision data option.
► Click Next.
The following screen is displayed:
Figure 3-24: Import of XML files for tables in SIPLACE Pro
► Click Finish.
The following screen is displayed:
Figure 3-25: Finished import of XML files for tables in SIPLACE Pro
► Click OK.

ACT with SSW 6xx / User Manual 07/2017 Edition
27
Figure 3-26 displays the tables in the ACT folder:
You can also see a waffle pack tray with 16x4 component rows (example CC02-05 glass
components).
1)
2)
Figure 3-26: Tables in ACT folder, view of waffle pack tray with example of 16x4 rows CC02-05 glass components
Key:
(1) ACT tables
(2) ACT waffle pack tray with 16x4 components
NOTICE
Glass components on waffle pack trays
Tray suggestions for an ACT with MTCs and WPCs can be found in the Trays tab.
The next figure displays the structure view of the waffle pack trays (right-hand side of diagram):
Figure 3-27: Waffle pack tray structure in SIPLACE Pro

ACT with SSW 6xx / User Manual 07/2017 Edition
28
4 Working with the ACT
4.1 Specifying the Placement and Measurement Program from
SIPLACE Pro
NOTICE
Placement program overview
The placement programs available vary according to the machine type and head/camera
configuration.
4.1.1 Selecting the Board (Placement Program)
4.1.1.1 Placement Program Overview for SIPLACE Pro < 11.x
Machine Head
Head
camera
Nozzle Placement program
X-series/
CAx with SW 605.xx
C&P20x
2 x C&P20x
SST 23,
SST 41
1004 / 1014
ACT_1xC&P20
(80 x Cerampad)
ACT_2xC&P20
(2 x 80 x Cerampad)
X-/D-series
C&P12-DLM,
CPP
(C&P mode)
2 x C&P12-DLM,
2 x CPP (C&P mode)
SST 28,
SST 29,
SST 30,
SST 38
904 / 914 /
2004 / 3004
ACT_1xC&P12
(96 x Cerampad)
ACT_2xC&P12
(2 x 96 x Cerampad)
X-/D-series
C&P6-DLM
TH-IC,
P&P-IC
SST 29,
SST 30
SST 33,
SST 36
920
518
ACT_CC02-05
(48 x CC02-05)
X-/D-series
TH-FC,
P&P-FC
SST 25 518
ACT_CC07-500
1)
(48 x CC07-500)
X-series
CPP
(P&P mode)
SST 33 2057
ACT_CC02-05_CPP
2)
(48 x CC02-05_CPP)
Table 4-1: Assignment of machine, board, head up to SIPLACE Pro < 11.x
1)
Up to software SIPLACE Pro 11.x and the corresponding station software versions, a separate optionally available
glass component CC07-500 (with BGA structure) was used for the SST 25 camera.
As of software SIPLACE Pro 11.x with station software version 706.02.SP1 Hotfix 2 or 707.1.SP1 Hotfix 2 or higher,
the CC02-05 component (with QFP structure) is used for the SST 25 camera (Flip-Chip camera).
If you plan to measure an SST 25 with ACT, we recommend upgrading the software to the versions described below.
2)
Listed in the table because the board is created with the SIPLACE Pro import.
However, a CPP head cannot be used with station software 6xx.