SOM-1802-002_w.pdf - 第62页

59 AJBES-P Recognition Error ID Description of Recognition Error , Cause, and Remedy 0 2 2 ** 71 1 "Elctd Row or Col Pitch" in "Elctd Group 1" is smoller than "Elctd Dim". 0 2 2 ** 712 &quot…

100%1 / 69
58 AJBES-P
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 1 ** 90a Error in Recognition Communication Data
0 2 1 ** 90b Error in Recognition Communication Data
0 2 1 ** 90c Error in Recognition Communication Data
0 2 1 ** 90d Error in Recognition Communication Data
0 2 1 ** 90e Error in Recognition Communication Data
0 2 1 ** 90f Error in Recognition Communication Data
0 2 1 ** 910 Error in Recognition Communication Data
0 2 1 ** 911 Error in Recognition Communication Data
0 2 1 ** 912 Error in Recognition Communication Data
0 2 1 ** 913 Error in Recognition Communication Data
0 2 1 ** 914 Error in Recognition Communication Data
0 2 1 ** 915 Error in Recognition Communication Data
0 2 1 ** 916 Error in Recognition Communication Data
0 2 1 ** 917 Error in Recognition Communication Data
0 2 1 ** 918 Error in Recognition Communication Data
0 2 1 ** 919 Error in Recognition Communication Data
0 2 1 ** 91a Error in Recognition Communication Data
0 2 1 ** 91b Error in Recognition Communication Data
0 2 1 ** 91c Error in Recognition Communication Data
0 2 1 ** 91d Error in Recognition Communication Data
0 2 1 ** 91e Error in Recognition Communication Data
0 2 1 ** 91f Error in Recognition Communication Data
0 2 1 ** *** Error in Recognition Communication Data
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
0 2 2 ** 505 Device Size is small.
0 2 2 ** 506 Device Size is big.
0 2 2 ** 507 The component cannot be recognized in the "Back Lighting" system because
the component size is big.
0 2 2 ** 508 component's thickness is large
0 2 2 ** 701 "# of Groups" (elctd data) is improper.
0 2 2 ** 702 No detection is set in all "Insp Condtn" text boxes.
0 2 2 ** 703 Elctd # of Rows or # of Cols is improper.
0 2 2 ** 704 "Electrode" is overlapped.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
7.4 Recognition Error IDs and Remedial Procedures
0606-002
59 AJBES-P
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 2 ** 711 "Elctd Row or Col Pitch" in "Elctd Group 1" is smoller than "Elctd Dim".
0 2 2 ** 712 "Elctd Row or Col Pitch" in "Elctd Group 2" is smoller than "Elctd Dim".
0 2 2 ** 713 "Elctd Row or Col Pitch" in "Elctd Group 3" is smoller than "Elctd Dim".
0 2 2 ** 714 "Elctd Row or Col Pitch" in "Elctd Group 4" is smoller than "Elctd Dim".
0 2 2 ** 715 "Elctd Row or Col Pitch" in "Elctd Group 5" is smoller than "Elctd Dim".
0 2 2 ** 716 "Elctd Row or Col Pitch" in "Elctd Group 6" is smoller than "Elctd Dim".
0 2 2 ** 717 "Elctd Row or Col Pitch" in "Elctd Group 7" is smoller than "Elctd Dim".
0 2 2 ** 718 "Elctd Row or Col Pitch" in "Elctd Group 8" is smoller than "Elctd Dim".
0 2 2 ** 719 "Elctd Row or Col Pitch" in "Elctd Group 9" is smoller than "Elctd Dim".
0 2 2 ** 71A "Elctd Row or Col Pitch" in "Elctd Group 10" is smoller than "Elctd Dim".
0 2 2 ** 71B "Elctd Row or Col Pitch" in "Elctd Group 11" is smoller than "Elctd Dim".
0 2 2 ** 71C "Elctd Row or Col Pitch" in "Elctd Group 12" is smoller than "Elctd Dim".
0 2 2 ** 71D "Elctd Row or Col Pitch" in "Elctd Group 13" is smoller than "Elctd Dim".
0 2 2 ** 71E "Elctd Row or Col Pitch" in "Elctd Group 14" is smoller than "Elctd Dim".
0 2 2 ** 71F "Elctd Row or Col Pitch" in "Elctd Group 15" is smoller than "Elctd Dim".
0 2 2 ** 720 "Elctd Row or Col Pitch" in "Elctd Group 16" is smoller than "Elctd Dim".
0 2 2 ** 721 "Elctd Row or Col Pitch" in "Elctd Group 17" is smoller than "Elctd Dim".
0 2 2 ** 722 "Elctd Row or Col Pitch" in "Elctd Group 18" is smoller than "Elctd Dim".
0 2 2 ** 723 "Elctd Row or Col Pitch" in "Elctd Group 19" is smoller than "Elctd Dim".
0 2 2 ** 724 "Elctd Row or Col Pitch" in "Elctd Group 20" is smoller than "Elctd Dim".
0 2 2 ** 725 "Elctd Row or Col Pitch" in "Elctd Group 21" is smoller than "Elctd Dim".
0 2 2 ** 726 "Elctd Row or Col Pitch" in "Elctd Group 22" is smoller than "Elctd Dim".
0 2 2 ** 727 "Elctd Row or Col Pitch" in "Elctd Group 23" is smoller than "Elctd Dim".
0 2 2 ** 728 "Elctd Row or Col Pitch" in "Elctd Group 24" is smoller than "Elctd Dim".
0 2 2 ** 729 "Elctd Row or Col Pitch" in "Elctd Group 25" is smoller than "Elctd Dim".
0 2 2 ** 72A "Elctd Row or Col Pitch" in "Elctd Group 26" is smoller than "Elctd Dim".
0 2 2 ** 72B "Elctd Row or Col Pitch" in "Elctd Group 27" is smoller than "Elctd Dim".
0 2 2 ** 72C "Elctd Row or Col Pitch" in "Elctd Group 28" is smoller than "Elctd Dim".
0 2 2 ** 72D "Elctd Row or Col Pitch" in "Elctd Group 29" is smoller than "Elctd Dim".
0 2 2 ** 72E "Elctd Row or Col Pitch" in "Elctd Group 30" is smoller than "Elctd Dim".
0 2 2 ** 741 Electrode position superposed in different electrode group.
0 2 2 ** 742 "Elctd Dim" is small.
0 2 2 ** 743 "Elctd Row or Col Pitch" is narrow.
0 2 2 ** 744 The electrode-to-electrode distance is short.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
7.4 Recognition Error IDs and Remedial Procedures
0606-002
60 AJBES-P
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 2 ** 751 "Missing Start Row or Col" in "Elctd Group 1" is large.
0 2 2 ** 752 "Missing Start Row or Col" in "Elctd Group 2" is large.
0 2 2 ** 753 "Missing Start Row or Col" in "Elctd Group 3" is large.
0 2 2 ** 754 "Missing Start Row or Col" in "Elctd Group 4" is large.
0 2 2 ** 755 "Missing Start Row or Col" in "Elctd Group 5" is large.
0 2 2 ** 756 "Missing Start Row or Col" in "Elctd Group 6" is large.
0 2 2 ** 757 "Missing Start Row or Col" in "Elctd Group 7" is large.
0 2 2 ** 758 "Missing Start Row or Col" in "Elctd Group 8" is large.
0 2 2 ** 759 "Missing Start Row or Col" in "Elctd Group 9" is large.
0 2 2 ** 75A "Missing Start Row or Col" in "Elctd Group 10" is large.
0 2 2 ** 75B "Missing Start Row or Col" in "Elctd Group 11" is large.
0 2 2 ** 75C "Missing Start Row or Col" in "Elctd Group 12" is large.
0 2 2 ** 75D "Missing Start Row or Col" in "Elctd Group 13" is large.
0 2 2 ** 75E "Missing Start Row or Col" in "Elctd Group 14" is large.
0 2 2 ** 75F "Missing Start Row or Col" in "Elctd Group 15" is large.
0 2 2 ** 760 "Missing Start Row or Col" in "Elctd Group 16" is large.
0 2 2 ** 761 "Missing Start Row or Col" in "Elctd Group 17" is large.
` 0 2 2 ** 762 "Missing Start Row or Col" in "Elctd Group 18" is large.
0 2 2 ** 763 "Missing Start Row or Col" in "Elctd Group 19" is large.
0 2 2 ** 764 "Missing Start Row or Col" in "Elctd Group 20" is large.
0 2 2 ** 765 "Missing Start Row or Col" in "Elctd Group 21" is large.
0 2 2 ** 766 "Missing Start Row or Col" in "Elctd Group 22" is large.
0 2 2 ** 767 "Missing Start Row or Col" in "Elctd Group 23" is large.
0 2 2 ** 768 "Missing Start Row or Col" in "Elctd Group 24" is large.
0 2 2 ** 769 "Missing Start Row or Col" in "Elctd Group 25" is large.
0 2 2 ** 76A "Missing Start Row or Col" in "Elctd Group 26" is large.
0 2 2 ** 76B "Missing Start Row or Col" in "Elctd Group 27" is large.
0 2 2 ** 76C "Missing Start Row or Col" in "Elctd Group 28" is large.
0 2 2 ** 76D "Missing Start Row or Col" in "Elctd Group 29" is large.
0 2 2 ** 76E "Missing Start Row or Col" in "Elctd Group 30" is large.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
7.4 Recognition Error IDs and Remedial Procedures
0606-002