SOM-1802-002_w.pdf - 第66页

63 AJBES-P 7.4 Recognition Error IDs and Remedial Procedures 0606-002 Recognition Error ID Description of Recognition Error , Cause, and Remedy 0 2 d * * *** Error in Recognition Communication Data. (Cause) Recognition C…

100%1 / 69
62 AJBES-P
Recognition Error ID Error Name, Description, Cause, and Remedy
0 2 2 ** 904 "Polarity Inspection Position" out of "Mold Size"
0 2 2 ** 905 Selected algorithm is improper.
0 2 2 ** 906 Failed in automatic selection of algorithm.
0 2 2 ** A01 The nozzle cannot be used because the method of illuminating is differenet
from lighting method of the component library.
0 2 2 ** *** Others.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0 2 3 ** 001 Recognition Communication Procedure Error.
0 2 3 ** 002 Recognition Communication Procedure Error.
0 2 3 ** 003 Recognition Communication Procedure Error.
0 2 3 ** 004 Recognition Communication Procedure Error.
0 2 3 ** 006 Recognition Communication Procedure Error.
0 2 3 ** 007 Recognition Communication Procedure Error.
0 2 3 ** *** Recognition Communication Procedure Error.
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
0 2 4 ** 001 An error occurred during data transfer between recognition and counter boards.
(Cause) An error occurred during data transfer between recognition and
counter boards.
(Remedy) Contact our service personnel for details.
0 2 4 ** 002 An error occurred during data transfer between recognition and lighting control
boards.
(Cause) An error occurred during data transfer between recognition and
lighting control boards.
(Remedy) Contact our service personnel for details.
0 2 4 ** 003 Lighting control board self-diagnostic abnormalities
(Cause) Lighting control board self-diagnostic abnormalities
(Remedy) Contact our service personnel for details.
0 2 4 ** *** Others.
(Cause) An error was found in the component recognition lighting.
(Remedy) Contact our service personnel for details.
0 2 9 ** 001 Image Aquiring in was interrupted.
0 2 9 ** 101 Image data file can't be saved.
0 2 9 ** 102 Image data file can't be saved.
0 2 9 ** 103 Image data file can't be saved.
(Cause) Self-Diagnostics Error Message.
(Remedy) Contact our service personnel for details.
0 2 9 ** *** Others.
(Cause) An error was found in the component recognition lighting.
(Remedy) Contact our service personnel for details.
7.4 Recognition Error IDs and Remedial Procedures
0606-002
63 AJBES-P
7.4 Recognition Error IDs and Remedial Procedures
0606-002
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 d ** *** Error in Recognition Communication Data.
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
0 2 e ** *** Error in Recognition Communication Data.
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
1 2 * ** *** Error in Recognition Communication Data
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
64 AJBES-P
(4) Component Recognition Errors
Z A B CC DDD
Detailed Classification: Detailed Classification
Small Classification: Small Classification
Middle Classification
0: Component Recognition (Component Missing)
1: Component Recognition
(Coarse Recognition Error)
2: Component Recognition
(Detailed Recognition Error)
8: Component Recognition (Inspection Error)
9: Component Recognition (Judgment Error)
A: Component Recognition (Judgment Error)
E: Component Recognition (Other Errors)
Large Classification (5)
Classification Criteria
When an error ID other than the described ones is issued, contact
our service personnel for some advice.
Table 21
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 5 0 ** 001 Component was not found.
(Cause 1) The feeder is loaded with the components different from the
specified ones.
(Cause 2) The vacuum suction force is too weak.
(Cause 3) The components collide with nozzles.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the
component library data.
0 5 0 ** *** Others.
0 5 1 ** 001 Component was not detected.
0 5 1 ** 201 No Electrode(ball) Detected.
0 5 1 ** *** Others.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0 5 2 ** 501 Electrode(ball) which is in agreement with data was undetectable.
0 5 2 ** 502 Since a sufficient number of Electrode(ball) were undetectable, it cannot
position.
0 5 2 ** *** Others.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
7.4 Recognition Error IDs and Remedial Procedures
Notice
0606-002