SOM-1802-002_w.pdf - 第64页
61 AJBES-P Recognition Error ID Description of Recognition Error , Cause, and Remedy 0 2 2 ** 771 "Elctd # of Rows or # of Cols" in "Elctd Group 1" is not sufficient. 0 2 2 ** 772 "Elctd # of Row…

60 AJBES-P
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 2 ** 751 "Missing Start Row or Col" in "Elctd Group 1" is large.
0 2 2 ** 752 "Missing Start Row or Col" in "Elctd Group 2" is large.
0 2 2 ** 753 "Missing Start Row or Col" in "Elctd Group 3" is large.
0 2 2 ** 754 "Missing Start Row or Col" in "Elctd Group 4" is large.
0 2 2 ** 755 "Missing Start Row or Col" in "Elctd Group 5" is large.
0 2 2 ** 756 "Missing Start Row or Col" in "Elctd Group 6" is large.
0 2 2 ** 757 "Missing Start Row or Col" in "Elctd Group 7" is large.
0 2 2 ** 758 "Missing Start Row or Col" in "Elctd Group 8" is large.
0 2 2 ** 759 "Missing Start Row or Col" in "Elctd Group 9" is large.
0 2 2 ** 75A "Missing Start Row or Col" in "Elctd Group 10" is large.
0 2 2 ** 75B "Missing Start Row or Col" in "Elctd Group 11" is large.
0 2 2 ** 75C "Missing Start Row or Col" in "Elctd Group 12" is large.
0 2 2 ** 75D "Missing Start Row or Col" in "Elctd Group 13" is large.
0 2 2 ** 75E "Missing Start Row or Col" in "Elctd Group 14" is large.
0 2 2 ** 75F "Missing Start Row or Col" in "Elctd Group 15" is large.
0 2 2 ** 760 "Missing Start Row or Col" in "Elctd Group 16" is large.
0 2 2 ** 761 "Missing Start Row or Col" in "Elctd Group 17" is large.
` 0 2 2 ** 762 "Missing Start Row or Col" in "Elctd Group 18" is large.
0 2 2 ** 763 "Missing Start Row or Col" in "Elctd Group 19" is large.
0 2 2 ** 764 "Missing Start Row or Col" in "Elctd Group 20" is large.
0 2 2 ** 765 "Missing Start Row or Col" in "Elctd Group 21" is large.
0 2 2 ** 766 "Missing Start Row or Col" in "Elctd Group 22" is large.
0 2 2 ** 767 "Missing Start Row or Col" in "Elctd Group 23" is large.
0 2 2 ** 768 "Missing Start Row or Col" in "Elctd Group 24" is large.
0 2 2 ** 769 "Missing Start Row or Col" in "Elctd Group 25" is large.
0 2 2 ** 76A "Missing Start Row or Col" in "Elctd Group 26" is large.
0 2 2 ** 76B "Missing Start Row or Col" in "Elctd Group 27" is large.
0 2 2 ** 76C "Missing Start Row or Col" in "Elctd Group 28" is large.
0 2 2 ** 76D "Missing Start Row or Col" in "Elctd Group 29" is large.
0 2 2 ** 76E "Missing Start Row or Col" in "Elctd Group 30" is large.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
7.4 Recognition Error IDs and Remedial Procedures
0606-002

61 AJBES-P
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 2 2 ** 771 "Elctd # of Rows or # of Cols" in "Elctd Group 1" is not sufficient.
0 2 2 ** 772 "Elctd # of Rows or # of Cols" in "Elctd Group 2" is not sufficient.
0 2 2 ** 773 "Elctd # of Rows or # of Cols" in "Elctd Group 3" is not sufficient.
0 2 2 ** 774 "Elctd # of Rows or # of Cols" in "Elctd Group 4" is not sufficient.
0 2 2 ** 775 "Elctd # of Rows or # of Cols" in "Elctd Group 5" is not sufficient.
0 2 2 ** 776 "Elctd # of Rows or # of Cols" in "Elctd Group 6" is not sufficient.
0 2 2 ** 777 "Elctd # of Rows or # of Cols" in "Elctd Group 7" is not sufficient.
0 2 2 ** 778 "Elctd # of Rows or # of Cols" in "Elctd Group 8" is not sufficient.
0 2 2 ** 779 "Elctd # of Rows or # of Cols" in "Elctd Group 9" is not sufficient.
0 2 2 ** 77A "Elctd # of Rows or # of Cols" in "Elctd Group 10" is not sufficient.
0 2 2 ** 77B "Elctd # of Rows or # of Cols" in "Elctd Group 11" is not sufficient.
0 2 2 ** 77C "Elctd # of Rows or # of Cols" in "Elctd Group 12" is not sufficient.
0 2 2 ** 77D "Elctd # of Rows or # of Cols" in "Elctd Group 13" is not sufficient.
0 2 2 ** 77E "Elctd # of Rows or # of Cols" in "Elctd Group 14" is not sufficient.
0 2 2 ** 77F "Elctd # of Rows or # of Cols" in "Elctd Group 15" is not sufficient.
0 2 2 ** 780 "Elctd # of Rows or # of Cols" in "Elctd Group 16" is not sufficient.
0 2 2 ** 781 "Elctd # of Rows or # of Cols" in "Elctd Group 17" is not sufficient.
` 0 2 2 ** 782 "Elctd # of Rows or # of Cols" in "Elctd Group 18" is not sufficient.
0 2 2 ** 783 "Elctd # of Rows or # of Cols" in "Elctd Group 19" is not sufficient.
0 2 2 ** 784 "Elctd # of Rows or # of Cols" in "Elctd Group 20" is not sufficient.
0 2 2 ** 785 "Elctd # of Rows or # of Cols" in "Elctd Group 21" is not sufficient.
0 2 2 ** 786 "Elctd # of Rows or # of Cols" in "Elctd Group 22" is not sufficient.
0 2 2 ** 787 "Elctd # of Rows or # of Cols" in "Elctd Group 23" is not sufficient.
0 2 2 ** 788 "Elctd # of Rows or # of Cols" in "Elctd Group 24" is not sufficient.
0 2 2 ** 789 "Elctd # of Rows or # of Cols" in "Elctd Group 25" is not sufficient.
0 2 2 ** 78A "Elctd # of Rows or # of Cols" in "Elctd Group 26" is not sufficient.
0 2 2 ** 78B "Elctd # of Rows or # of Cols" in "Elctd Group 27" is not sufficient.
0 2 2 ** 78C "Elctd # of Rows or # of Cols" in "Elctd Group 28" is not sufficient.
0 2 2 ** 78D "Elctd # of Rows or # of Cols" in "Elctd Group 29" is not sufficient.
0 2 2 ** 78E "Elctd # of Rows or # of Cols" in "Elctd Group 30" is not sufficient.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
7.4 Recognition Error IDs and Remedial Procedures
0606-002

62 AJBES-P
Recognition Error ID Error Name, Description, Cause, and Remedy
0 2 2 ** 904 "Polarity Inspection Position" out of "Mold Size"
0 2 2 ** 905 Selected algorithm is improper.
0 2 2 ** 906 Failed in automatic selection of algorithm.
0 2 2 ** A01 The nozzle cannot be used because the method of illuminating is differenet
from lighting method of the component library.
0 2 2 ** *** Others.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0 2 3 ** 001 Recognition Communication Procedure Error.
0 2 3 ** 002 Recognition Communication Procedure Error.
0 2 3 ** 003 Recognition Communication Procedure Error.
0 2 3 ** 004 Recognition Communication Procedure Error.
0 2 3 ** 006 Recognition Communication Procedure Error.
0 2 3 ** 007 Recognition Communication Procedure Error.
0 2 3 ** *** Recognition Communication Procedure Error.
(Cause) Recognition Communication Error
(Remedy) Contact our service personnel for details.
0 2 4 ** 001 An error occurred during data transfer between recognition and counter boards.
(Cause) An error occurred during data transfer between recognition and
counter boards.
(Remedy) Contact our service personnel for details.
0 2 4 ** 002 An error occurred during data transfer between recognition and lighting control
boards.
(Cause) An error occurred during data transfer between recognition and
lighting control boards.
(Remedy) Contact our service personnel for details.
0 2 4 ** 003 Lighting control board self-diagnostic abnormalities
(Cause) Lighting control board self-diagnostic abnormalities
(Remedy) Contact our service personnel for details.
0 2 4 ** *** Others.
(Cause) An error was found in the component recognition lighting.
(Remedy) Contact our service personnel for details.
0 2 9 ** 001 Image Aquiring in was interrupted.
0 2 9 ** 101 Image data file can't be saved.
0 2 9 ** 102 Image data file can't be saved.
0 2 9 ** 103 Image data file can't be saved.
(Cause) Self-Diagnostics Error Message.
(Remedy) Contact our service personnel for details.
0 2 9 ** *** Others.
(Cause) An error was found in the component recognition lighting.
(Remedy) Contact our service personnel for details.
7.4 Recognition Error IDs and Remedial Procedures