SMN-Tape Feeder Manual(Eng Ver5).pdf - 第29页

Overview 1-1 1 1.4.2. IT Function  Probe Pin Components 1 3 5 7 9 11 2 4 6 8 10 Figur e 1-9. IT Pr obe Pin Layout T able 1-6. Probe Pin Assignment (IT) Pin No. Function Use Pin No. Function Use 1 ID0 O 7 Indexing Signal…

100%1 / 89
Samsung SM-Series Pneumatic Tape Feeder Users' Manual
1-10
1.4. IT and Non-IT Standard
1.4.1. NON-IT Function
Probe Pin Components
7
9
11
8
10
Figure 1-8. Non-IT Probe Pin Layout
Table 1-5. Probe Pin Assignment (Non IT)
Pin
No.
Function Use
Pin
No.
Function Use
1 ID0 X 7 Indexing Signal O
2 ID1 X 8 Clamping Signal O
3 D24V X 9 Indexing Command O
4 Communication X 10 F24V O
5 Communication X 11 F24G O
6 D24G X
LED Status
Status
Color
Off Green Orange
Clamped & Shutter Close O
Shutter Open O
Unclamped O
Overview
1-11
1.4.2. IT Function
Probe Pin Components
1
3
5
7
9
11
2
4
6
8
10
Figure 1-9. IT Probe Pin Layout
Table 1-6. Probe Pin Assignment (IT)
Pin
No.
Function Use
Pin
No.
Function Use
1 ID0 O 7 Indexing Signal O
2 ID1 O 8 Clamping Signal O
3 D24V O 9 Indexing Command O
4 Communication O 10 F24V O
5 Communication O 11 F24G O
6 D24G O
LED Status
Feeder State LED Display * To indicate:
Not Powered Off Power is not supplied to the feeder
Normal(Ready) Green Feeder is ready
Not Connected Green Blink Not connected to CAN Master
Feeding(Busy) Orange Parts supply in progress (Busy)
Warning Orange Blink Feeder is in warning status (Warning)
Mismatching Red Blink Discrepancy between the feeder
arrangement information in the PCB program
and the actual feeder arrangement
Error Red Feeder is in error status (Error)
Samsung SM-Series Pneumatic Tape Feeder Users' Manual
1-12
Manual Feeding
Figure 1-10. Manual feeding button (8~16mm)
Figure 1-1. Manual feeding button (8~16mm)
Operation of driving feeder with manual switch is possible only in IT feeder.
Power must be supplied at this time.
One click initiates one operation cycle.
- Shutter Open Step + Shutter Close Step(Feeding).
- At the first click, there is a time delay of 500msec.
While being pressed, continuous feeding is performed.
Delay time between the steps is intended to secure sufficient feeding time based
on the large feeder (72mm), which has a lengthy feeding time.
- 500 msec
State LED
Manual Feeding Switch
State LED
Manual Feeding Switch