Inspection of the Contr oller Alarm Code 53H (DB overheat)  Operating state when alarm occurred Possible causes When control power supply is turned on High High 1 Faulty amplifier internal circuit DB operating frequency…

100%1 / 128
Samsung Component Placer CP45FV Series Maintenance Guide
Caution
For the setting that internal or external regenerative resistor
is used, detect regenerative error if it is not actually
connected.
For the setting that regenerative resistor is not used,
regenerative error is not detected when it is actually
connected. In other words that may damage or bum the
amplifier and its peripheral circuit.
Alarm Code 51H (Amplifier Temperature Error)
Operating state when alarm occurred
Possible causes
Operating state
1 2 3 4
When control power supply is turned on Low
High Low
During operation Low High High High
After emergency stoppage
High
Corrective measures
Cause Corrective measures
1
Faulty internal circuit of Servo
Amplifier
Replace amplifier.
2 Regenerative power is too large
Review operational conditions
Use external regenerative resistor
3
Although regenerative power is
within specification, ambient
temperature of Servo Amplifier is
out of specification.
Review cooling method so that
temperature in control board is from
32°F (0) to 131°F (55).
4
Though regenerative power is
within specification, the cooling
fun in Servo Amplifier stops.
Check if the cooling fan in amplifier is
rotating. Replace the amplifier if fan is
not operating.
5
Regenerative power when
emergency stoppage was too
large.
Replace Amplifier
Review load condition
Caution
Detect the error by amplifier internal temperature regardless
of ambient temperature. If warning of amplifier ambient
temperature is detected, make sure to review the cooling
method in the control board.
7-38
Inspection of the Controller
Alarm Code 53H (DB overheat)
Operating state when alarm occurred
Possible
causes
When control power supply is turned on High
High
1 Faulty amplifier internal circuit
DB operating frequency is too high.
Use the dynamic brake without
exceeding its allowable frequency by
referring to 9.1.8.
Possible causes
Operating state
3
When control power supply is turned on
During operation Low
Corrective measures
Cause
1 Faulty amplifier internal circuit Replace servo amplifier
2
Operate under the condition that
regenerative electric power is
below the specified capacity.
Use an external regenerative
resistor.
Caution
Operating state
1 2
During operation Low
Corrective measures
Cause Corrective measures
Replace servo amplifier
2
Alarm Code 54H (Internal overheat)
Operating state when alarm occurred
1 2
Low High
High High
Corrective measures
Confirm the specified capacity of
internal regenerative resistor.
Regenerative power is too large.
Faulty wiring of built-in regenerative
resistor
Check wrong wiring and correct it.
3
When using regenerative resistor built in Servo Amplifier,
as Regenerative Resistor type set “built-in regenerative
resistor” to the amplifier exactly.
With this setting, it is decided that overheat protecting
detection of built-in regenerative resistor is effective or
ineffective. In case no regenerative resistor connection or
external regenerative resistor is selected, overheat
detection of built-in regenerative resistor will not function.
7-39
Samsung Component Placer CP45FV Series Maintenance Guide
Caution
Regenerative resistor which is built in the amplifier of 15A
or 30A does not have a thermostat.
Alarm Code 55H (External error)
Checking The Selection of Active Condition under the external trip function, confirm
if the external trip function is active, and also which input is used. Confirm what
function is used for the general purpose input terminal in validity when external trip
is activated
When connect external regenerative thermal
1
When control power supply is turned on High
High Low
Corrective measures
Cause Corrective measures
1
2
External thermal terminal
(external regenerative resistor)
operated.
3
Faulty servo amplifier control
board
Replace servo amplifier
Remove alarm causes in upper system.
Alarm Code 61H (Over voltage)
1
When control power supply is turned on High
When main circuit power supply is turned on High
When motor is started or stopped
High
Detect the error by estimating from regenerative load ratio.
Operating state when alarm occurred
Possible causes
Operating state
2 3
Low
After operating for a short period
Incorrect wiring of external
regenerative resistor.
Check wrong wiring and correct it.
Review operational conditions.
Increase capacity of external
regenerative resistor
When connect output terminal of upper system
Operating state when alarm occurred
Possible causes
Operating state
2 3 4
High
Low High