Maintenance Reference(CP45FV) Eng.pdf - 第49页
W eekly Inspection 3-1 1 occurred (inspect the area where it contacts the PCB). Inspection Point Figur e 3-8. St opper Inspection Points Solution If excessive wear is detected, replace the upper section of the stopper …

Samsung Component Placer CP45FV Series Maintenance Reference
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” and “Reset” buttons on the front operation
panel. Conduct inspection while the motor power supply is
turned off.
FREE
Reset
Button
Eliminate the contamination and clean the sensor window with a soft cloth.
Check the sensitivity of sensor.
The conditions for detection may vary depending on the installation method, distance,
and angle and location of each sensor as well as due to dust, external light, shape, and
color of the board. Therefore, sensitivity of a sensor should be adjusted by using the
actual board that will be used. When adjusting the sensitivity of the board detecting
sensor, if there is no PCB, neither the red nor the green LEDs shall be turned on. The
“lightness/darkness“ adjusting screw shall always be turned to the “L” side.
If there is a PCB, turn the sensitivity adjusting screw clockwise so that both the red
and green LEDs are turned on.
If the “lightness/darkness“ adjusting screw is not turned to the “L” side, only the red
LED is turned on.
For reference, the sensitivity of the input sensor, quick load sensor and output sensor
cannot be adjusted.
Sensor Window
Red LED
Green LED
Sensitivity Control Screw
Lightness/Darkness Adjusting Screw
If the sensor is found defective, contact the service center for a replacement.
3.2.4.4. Stopper (Hard Stop) Inspection
Inspection
Check the upper section of the stopper (or hard stop) to see if excessive wear has
3-10

Weekly Inspection
3-11
occurred (inspect the area where it contacts the PCB).
Inspection Point
Figure 3-8. Stopper Inspection Points
Solution
If excessive wear is detected, replace the upper section of the stopper..
3.2.4.5. Conveyor Cylinder Operation
Inspection
Check the operation of each cylinder.
Check the detect sensor of each cylinder.
Solution
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” and “Reset” buttons on the front operation
panel. Conduct inspection while the motor power supply is
turned off.
FREE
Reset
Button

Samsung Component Placer CP45FV Series Maintenance Reference
Edge Fixer Cylinder
Stopper
Cylinder
ANC
Cylinder
Backup
Table
Cylinder
The operation of each cylinder can be checked using <Setup/Manual Control>
command or <Setup/Diagnostics/Self Diagnosis> command on the MMI application.
Select <Diagnosis> from the MMI main menu tool-bar, and select “<I/O>(F2)” from
the sub menu tool-bar on the left displayed.
3-12