Maintenance Reference(CP45FV) Eng.pdf - 第111页

Inspection of the Contr oller Corrective measures Cause 1 Faulty amplifier control board Replace servo amplifier. Reduce voltage to within allowabl e range. 3 4 Faulty wiring of connector CND, or Inner regenerative circu…

100%1 / 128
Samsung Component Placer CP45FV Series Maintenance Guide
Caution
Regenerative resistor which is built in the amplifier of 15A
or 30A does not have a thermostat.
Alarm Code 55H (External error)
Checking The Selection of Active Condition under the external trip function, confirm
if the external trip function is active, and also which input is used. Confirm what
function is used for the general purpose input terminal in validity when external trip
is activated
When connect external regenerative thermal
1
When control power supply is turned on High
High Low
Corrective measures
Cause Corrective measures
1
2
External thermal terminal
(external regenerative resistor)
operated.
3
Faulty servo amplifier control
board
Replace servo amplifier
Remove alarm causes in upper system.
Alarm Code 61H (Over voltage)
1
When control power supply is turned on High
When main circuit power supply is turned on High
When motor is started or stopped
High
Detect the error by estimating from regenerative load ratio.
Operating state when alarm occurred
Possible causes
Operating state
2 3
Low
After operating for a short period
Incorrect wiring of external
regenerative resistor.
Check wrong wiring and correct it.
Review operational conditions.
Increase capacity of external
regenerative resistor
When connect output terminal of upper system
Operating state when alarm occurred
Possible causes
Operating state
2 3 4
High
Low High
7-40
Inspection of the Controller
Corrective measures
Cause
1 Faulty amplifier control board Replace servo amplifier.
Reduce voltage to within allowable
range.
3
4
Faulty wiring of connector CND, or
Inner regenerative circuit does not
function.
Wiring regenerative resistor correctly:
Connect regenerative resistor wires to P
and Y terminals of connector CND.
When external regenerative resistor is
used, check wiring and resistance
value. Replace Servo Amplifier if
malfunction persists.
Operating state when alarm occurred
Possible causes
Operating state
2 3 4
After main circuit power supply is turned on High High
During motor operation (alarm can be reset)
Low
During motor operation (alarm can not be
reset)
Corrective measures
1
2 Main circuit rectifier is broken Replace servo amplifier.
Check main power supply not to occur
momentary interruption or power drop.
4
5
Faulty internal circuit of servo
amplifier
Replace servo amplifier
Corrective measures
Power voltage of main circuit is
exceeding allowable voltage
2
Reduce load inertia to within allowable
range.
Load inertia is too large.
Alarm Code 62H (Main circuit short voltage)
1 5
When control power supply is turned on High Low
High
High
Corrective measures
Cause
Power supply voltage is below
specified range
Set power supply to proper voltage
within specified range.
Input voltage dropped. Or
momentary interruption occurred.
3
Check main circuit voltage not to supply
around power from other to R. S. T
when main circuit OFF.
Low voltage without specification is
supplying to main circuit (R.S.T)
7-41
Samsung Component Placer CP45FV Series Maintenance Guide
Alarm Code 63H (Phase missing of main power supply)
Operating state when alarm occurred
Possible causes
Operating state
1 2 3
When control power supply is turned on
When main power supply is turned on
During motor operation Low
Alarm occurred although specified single phase power input
Corrective measures
Cause Corrective measures
Check wrong wiring and correct it.
2
3
Servo amplifier is not specified for
single phase
Confirm model number and delivery
specification of that servo amplifier.
Replace with proper amplifier for
single phase.
Alarm Code 71H (Control power supply error)
Operating state when alarm occurred
Operating state
1 2 3
High
High
1 Faulty amplifier internal circuit
2
Power supply input voltage is below
specified range
Set voltage within specified range.
3
Alarm Code 72H (±12V power supply error)
Possible
causes
1 2
Low High
High
High High
High
Input missing one of the R, S, T
phases
1
Faulty amplifier internal circuit Replace servo amplifier
Change parameter for single phase
Amplifier.
Possible causes
When control power supply is turned on Low
During operation Low
Corrective measures
Cause Corrective measures
Replace servo amplifier.
Fluctuation or momentary interruption
of input power voltage occurred.
Check power supply
Operating state when alarm occurred
Operating state
When control power supply is turned on
7-42