Maintenance Reference(CP45FV) Eng.pdf - 第31页
Pr eventive Maintenance 1-3 Figur e 1-1. The solution for swi tching the power termi nal connection of a transf ormer <Example> Input power Single phase AC 220V Power Consumption: 6.3 KV A (Maximum)

Samsung Component Placer CP45FV Series Maintenance Reference
Warning
Please turn off the Main Switch in the right lower cover
of rear side before performing any maintenance related
tasks. Loss of human life may occur if proper safety
measures are not taken.
OFF
Main Switch
1.2. Environmental conditions
1.2.1. Requirements for air pressure
Pressure
Primary pressure: 0.5 ~ 0.7 MPa
Secondary pressure: 0.45 ~ 0.55 MPa
Air Consumption: Maximum 160 N ℓ/min
Dry Air: air dew point of -17℃ or less
1.2.2. Power requirements
Voltage
Single phase AC 220 V ±10 %
AC 100 V ±10 % / 110 V±10 % / 120 V±10 % / 200 V±10 % / 220
V±10 %/ 240 V±10 % (shall be changed the terminal of the transformer)
1-2

Preventive Maintenance
1-3
Figure 1-1. The solution for switching the power terminal connection of a transformer
<Example>
Input power
Single phase AC
220V
Power Consumption: 6.3 KVA (Maximum)

Samsung Component Placer CP45FV Series Maintenance Reference
Frequency: 50 / 60 Hz
Danger
If unspecified voltage is used or power input is changed
improperly, fire could occur and a death from electric shock
could occur.
Change of power input must be done by a trained repair and
maintenance operator or our authorized C/S personnel.
1.2.3. Environmental conditions
During operation
Temperature: +10 ℃ ~ +35 ℃
Humidity
Less than 50% RH (35 ℃)
Less than 90% RH (20 ℃)
During shipment or storage (in states other than during operation)
Temperature: -10 ℃ ~ +60 ℃
Humidity: 20% RH ~ 90% RH (non-condensation state)
1.3. Tools for Maintenance
1.3.1. Cleaning Kit (Material number: J8100118A)
A cleaning kit that is needed to perform maintenance of this machine is supplied together
with the machine. The following provides a description of the items comprising the
cleaning kit and their use.
1-4