Maintenance Reference(CP45FV) Eng.pdf - 第28页
在线预览 Maintenance Reference(CP45FV) Eng.pdf PDF 文档。

Preface
xv
main power supplied to the machine.
Main Circuit
Breaker
(Based on CE Machine)
Noise Filter
Refers to an electric device that allows electrical current to flow stably by preventing
any distortion of the current wave generated in the circuit.
F.G(Frame Ground)
Refers to the point at which the machine is grounded.
F.G

Preventive Maintenance
1-1
Chapter 1. Preventive Maintenance
1.1. Maintenance Procedure(ce model)
The following procedures should be performed before doing any maintenance task.
1. Check to see if all the operations of the equipment are terminated.
2. Turn off the Isolation Switch.
3. Turn off the Main Circuit Breaker.
4. Perform the maintenance tasks according to the directions explained in the following
sections. .
After completing the maintenance tasks, please follow the procedures outlined below in
order to operate the equipment properly.
1. Check to see if there are any abnormal substances in the maintenance area, and if any,
remove them.
2. Make sure that all the parts are re-assembled properly.
3. Turn on the Main Circuit Breaker.
4. Turn on the power of the equipment according to the procedures mentioned in power
inspection.
5. Confirm that the equipment is operated normally without any problem.