Preventive Maintenance
1-3
Figure 1-1. The solution for switching the power terminal connection of a transformer
<Example>
Input power
Single phase AC
220V
Power Consumption: 6.3 KVA (Maximum)
Samsung Component Placer CP45FV Series Maintenance Reference
Frequency: 50 / 60 Hz
Danger
If unspecified voltage is used or power input is changed
improperly, fire could occur and a death from electric shock
could occur.
Change of power input must be done by a trained repair and
maintenance operator or our authorized C/S personnel.
1.2.3. Environmental conditions
During operation
Temperature: +10 ~ +35
Humidity
Less than 50% RH (35 )
Less than 90% RH (20 )
During shipment or storage (in states other than during operation)
Temperature: -10 ~ +60
Humidity: 20% RH ~ 90% RH (non-condensation state)
1.3. Tools for Maintenance
1.3.1. Cleaning Kit (Material number: J8100118A)
A cleaning kit that is needed to perform maintenance of this machine is supplied together
with the machine. The following provides a description of the items comprising the
cleaning kit and their use.
1-4
Preventive Maintenance
1-5
Air Ejector Brush
Small Brush
Air Ejector
Used to blow away any dirt on the surface of the camera lens.
Brush
Used to remove any chips or foreign matter on the feeder base surface.
Small Brush
Used to remove dust on the mirror surface.
Swab
Alcohol Clean Cloth Embossed glove
Swab / alcohol
Used to clean the fly camera lens surface.
Clean Cloth
Used to clean any foreign matter on the mirror or lens.
Embossed glove
Used to clean the camera or mirror.