Notes: Chapter 1 1.7 T emperature Regulator Setup (Main) Edition 1.0 1-14 GL-541E Level 3 Reference

100%1 / 74
1.7 Temperature Regulator Setup (Main)
Changes can be made to the setup temperature by pressing the setup keys.
Procedure:
1. Hold down the relevant setup key (up or down) until the desired
temperature is reached.
Note:
1. During normal operation the same temperature has to be specified at both temperature
regulators (the main temperature regulator and the temperature regulator for the cooler).
If the specified temperatures differ, the temperature regulators will not function properly.
2. When the machine is to operate at room temperature, the temperature at the regulator for
the cooler should be lowered by three degrees. Thus the temperature is adjusted properly.
Example: To achieve a gluing temperature of 26° at the same room temperature, set the
main temperature regulator to 26° and the cooler temperature regulator to 23°.
OUT
°C
PV
SV
ALM1 ALM2
omRon
E5CJ
1
2
3
4
5
6
7
8
GL541-m59E
1. Temperature display
2. #1 warning lamp
3. #2 warning lamp
4. Setup key (up /down)
5. Mode key
6. Level key
7. Output operation display lamp
8. Setup display
Chapter 1 1.7 Temperature Regulator Setup (Main)
Edition 1.0 1-13 GL-541E Level 3 Reference
Notes:
Chapter 1 1.7 Temperature Regulator Setup (Main)
Edition 1.0 1-14 GL-541E Level 3 Reference
1.8 Temperature Regulator Setup (for the
Cooler)
By pressing the temperature status switch key the displayed items toggle as
shown in the following figure.
Procedure:
1. Press the temperature status switch key, and after confirming that the
"SP" display lamp comes on, set the desired temperature using the setup
keys.
The temperature must be the same as the other regulator.
Note: It is necessary to input the same temperature for both of the temperature regulators . If
the specified temperatures differ, the temperature regulators will not work properly.
2. Press the temperature status switch key again so that the "SP" display lamp goes
out. This completes the procedure.
2
1
87
3
4
5
6
°C
AL
OMRON E5CS
GL541-m07E
1. Variation lamp
2. Temperature display
3. Control output display lamp
4. Catch for opening front cover
5. Setup key (up)
6. Setup key (down)
7. Temperature status switch key
8. Switch display lamp
ON
SP
Present temperature
Setup temperature
Press key
GL541-m47E
Chapter 1 1.8 Temperature Regulator Setup (for the Cooler)
Edition 1.1 1-15 GL-541E Level 3 Reference