TR3-GL541-1_1E.pdf.pdf - 第60页

Chapter 3 3.2 Definitions of Proper Data Edition 1.1 3-15 GL-541E Level 3 Reference 13. MG4MAID Machine_ID = 0 Parameter to set special machine software modes. Normally set to 0. Input a decimal number after making the s…

100%1 / 74
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-14 GL-541E Level 3 Reference
12. MG4MASB Machine_Status_B = 0
Parameter to set special machine software modes.
Normally set to 0.
Input a decimal number after making the setting using a 16 bit binary format.
Refer to the following table for the settings. Use the calculator function in the
Windows Accessories icon group to perform this conversion.
Standard setting: 0
Mode Bit Map Hexadecimal
1000 0000 0000 0000 8000H
0100 0000 0000 0000
4000H
0010 0000 0000 0000
0001 0000 0000 0000
2000H
1000H
0000 1000 0000 0000 0800H
0000 0100 0000 0000 0400H
0000 0010 0000 0000
0200H
0000 0001 0000 0000 0100H
0000 0000 1000 0000
0080H
0000 0000 0100 0000 0040H
0000 0000 0010 0000 0020H
0000 0000 0001 0000 0010H
0000 0000 0000 1000 0008H
0000 0000 0000 0100
0004H
0000 0000 0000 0010 0002H
0000 0000 0000 0001 0001H
Using reference pin
Do not stop automatic operation
even if waiting for temperature
setting
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-15 GL-541E Level 3 Reference
13. MG4MAID Machine_ID = 0
Parameter to set special machine software modes.
Normally set to 0.
Input a decimal number after making the setting using a 16 bit binary format.
Use the calculator function in the Windows Accessories icon group to perform this
conversion.
Standard setting: 0
14. MG4PCBL PCB_Location = 0
Specify whether the reference pin is used or not used.
[0] Corner: Reference pin is not used.
[1] Pin: Reference pin is used.
Standard setting: 0
20. MG4LOSA Loader_Status_A = 0
Board loader operating conditions. Not used at present.
21. MG4LOSB Loader_ Status_B = 0
Board loader operating conditions. Not used at present.
22. MG4CVT Conveyor_Type = 0
Specify the direction of board flow.
[0] L R: Board flow is from left to right (standard).
[1] R L: Board flow is from right to left (optional).
Standard setting: 0
23. MG4WASG Wait_Signal = 0
Specify whether the wait signal is valid or invalid.
[0] Off: Wait signal is not valid.
[1] On: Wait signal is valid.
24. MG4BUI Busy_Invalid = 0
Specify whether or not the machine refers to board request signals from the next
machine (when unloading a board).
[0] No: Refer to board request signals from next machine.
[1] Yes: Ignore board request signals and feed out boards when they become
available.
Standard setting: 0
25. MG4CVC Conveyor_Control = 0
Specify whether the machine is fitted with the automatic conveyor width
adjustment mechanism.
[0] Manu: Manual conveyor adjustment
[1] Auto: Automatic conveyor adjustment
Standard setting: 0
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-16 GL-541E Level 3 Reference
26. MG4CVAL Conveyor_Adj_Limit (0.05 to 1.00) [mm] = 50
Specify the tolerance for the conveyor width setting when using automatic
conveyor width adjustment.
Standard setting: 50
27. MG4CVSO Conveyor_Stop_Offset (0.00 to 2.00) [mm] = 30
Specify the offset value for stopping the motor at the target position when using
automatic conveyor width adjustment.
Standard setting: 30
28. MG4CVAT Conveyor_adj_Timer (0 to 120000) [msec] = 60000
Specify the time for automatic conveyor width adjustment. If this time is
exceeded, a time-up error occurs.
Standard setting: 60000
29. MG4WMAL Width_Max_Limit (0.00 to 655.35) [mm] = 360
Specify the maximum conveyor width.
Standard setting: 360.00
30. MG4WMIL Width_Min_Limit (0.00 to 655.35) [mm] = 50
Specify the minimum conveyor width.
Standard setting: 50.00
40. MG4LMS LMS_Flag = 0
Specify whether the machine is HELPS-compatible or not HELPS-compatible.
[0] Off: Non HELPS-compatible machine
[1] On: HELPS-compatible machine
Standard setting: 0
41. MG4CELL Cell_Status = 0
Specify the cell status.
[0] Unit: Unit cell
[1] Active: Active cell
[2] Passive: Passive cell
Standard setting: 0
42. MG4CHGOM Change_Over_Mode (0 to 200) = 0
Specify the board type report for a HELPS machine.
[0]: Manual terminate
[2]: Pattern code (upper surface)
[4]: Bar code 1 (upper surface)
[5]: Bar code 2 (lower surface)
[25]: Bar code 3 (when using two bar codes; both surfaces)
Standard setting: 0