Chapter 3 3.2 Definitions of Proper Data Edition 1.1 3-24 GL-541E Level 3 Reference 192. MG4SCTZ3 Spot_cd_timer_Z3 (0 to 1000) [msec] = 0 Specify the delay timer for the Z3-axis lower limit. Standard setting: 0 193. MG4S…

100%1 / 74
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-23 GL-541E Level 3 Reference
174. MG4LMAX Travel_limit_max_X (-10000 to 10000) [pulse] = 0
Specify the maximum limit of the X-axis travel range.
Standard setting: 0
175. MG4LMAY Travel_limit_max_Y (-10000 to 10000) [pulse] = 0
Specify the maximum limit of the Y-axis travel range.
Standard setting: 0
176. MG4LMAQ Travel_limit_max_Q (-10000 to 10000) [pulse] = 0
Presently not used.
177. MG4LMAZ1 Travel_limit_max_Z1 (-10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z1-axis travel range.
Standard setting: 0
178. MG4LMAZ2 Travel_limit_max_Z2 (-10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z2-axis travel range.
Standard setting: 0
179. MG4LMAZ3 Travel_limit_max_Z3 (-10000 to 10000) [pulse] = 0
Specify the maximum limit of the Z3-axis travel range.
Standard setting: 0
181. MG4SDZ1 Spot_down_XY_point_Z1 (5 to 10000) [pulse] = 250
Presently not used.
182. MG4SDZ2 Spot_down_XY_point_Z2 (5 to 10000) [pulse] = 250
Presently not used.
183. MG4SDZ3 Spot_down_XY_point_Z3 (5 to 10000) [pulse] = 250
Presently not used.
184. MG4SDQZ1 Spot_down_Q_point_Z1 (5 to 10000) [pulse] = 250
Presently not used.
185. MG4SDQZ1 Spot_down_Q_point_Z2 (5 to 10000) [pulse] = 250
Presently not used.
186. MG4SDQZ3 Spot_down_Q_point_Z3 (5 to 10000) [pulse] = 250
Presently not used.
190. MG4SCTZ1 Spot_cd_timer_Z1 (0 to 1000) [msec] = 0
Specify the delay timer for the Z1-axis lower limit.
Standard setting: 0
191. MG4SCTZ2 Spot_cd_timer_Z2 (0 to 1000) [msec] = 0
Specify the delay timer for the Z2-axis lower limit.
Standard setting: 0
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-24 GL-541E Level 3 Reference
192. MG4SCTZ3 Spot_cd_timer_Z3 (0 to 1000) [msec] = 0
Specify the delay timer for the Z3-axis lower limit.
Standard setting: 0
193. MG4SUEZ1 Spot_up_end_timer_Z1 (0 to 1000) [msec] = 0
Specify the delay timer for the Z1-axis upper limit.
Standard setting: 0
194. MG4SUEZ2 Spot_up_end_timer_Z2 (0 to 1000) [msec] = 0
Specify the delay timer for the Z2-axis upper limit.
Standard setting: 0
195. MG4SUEZ3 Spot_up_end_timer_Z3 (0 to 1000) [msec] = 0
Specify the delay timer for the Z3-axis upper limit.
Standard setting: 0
196. MG4SLEZ1 Spot_low_end_height_Z1 (-500 to 500) [mm] = -20
Specify the height of the Z1-axis glue dispensing position above the board surface.
Standard setting: -20
197. MG4SLEZ2 Spot_low_end_height_Z2 (-500 to 500) [mm] = -20
Specify the height of the Z2-axis glue dispensing position above the board surface.
Standard setting: -20
198. MG4SLEZ3 Spot_low_end_height_Z3 (-500 to 500) [mm] = -20
Specify the height of the Z3-axis glue dispensing position above the board surface.
Standard setting: -20
199. MG4SOZ1 Spot_on_XY_position_Z1 (0 to 10000) [0.01 mm]
= 732
Specify the point where the Z1-axis glue valve turns on before the XY-axis reaches
the target position.
Standard setting: 732
200. MG4SOZ2 Spot_on_XY_position_Z2 (0 to 10000) [0.01 mm]
= 732
Specify the point where the Z2-axis glue valve turns on before the XY-axis reaches
the target position.
Standard setting: 732
201. MG4SOZ3 Spot_on_XY_position_Z3 (0 to 10000) [0.01 mm]
= 732
Specify the point where the Z3-axis glue valve turns on before the XY-axis reaches
the target position.
Standard setting: 732
202. MG4SOQZ1 Spot_on_Q_position_Z1 (0 to 360) [degrees] = 40
Specify the point where the Z1-axis glue valve turns on before the Q-axis reaches
the target position.
Standard setting: 40
Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-25 GL-541E Level 3 Reference
203. MG4SOQZ2 Spot_on_Q_position_Z2 (0 to 360) [degrees] = 40
Specify the point where the Z2-axis glue valve turns on before the Q-axis reaches
the target position.
Standard setting: 40
204. MG4SOQZ3 Spot_on_Q_position_Z3 (0 to 360) [pulse] = 40
Specify the point before the Q-axis reaches the glue position where the Z2-axis
glue valve turns on.
Standard setting: 40
Note: Depending on the Z-axis stroke and the glue type, there may be instances where
stringing occurs. In such a case, use Spot_on_XY_position_Z1, Z2, Z3 and
Spot_on_Q_position_Z1, Z2, Z3 to help prevent stringing. To make use of these
settings, set the appropriate bit in the Proper data Machine Status A. Normally internal
machine values are used.
205. MG4SOBO Spot_on_border (0 to 1000) [msec] = 0
Presently not used.
254. MG4GCPX Glue_check_orgn_position_X (0 to 65535) [pulse]
= 36500
Specify the X coordinate of the position from where the glue check and needle
offset measurement will begin.
Standard setting: 36500
255. MG4GCPY Glue_check_orgn_position_Y (0 to 40000) [pulse]
= 39200
Specify the Y coordinate of the position from where the glue check and needle
offset measurement will begin.
Standard setting: 39200
256. MG4NOXZ1 Needle_offset_X_Z1 (-32768 to 32767) [pulse] = 0
Specify the X coordinate of the needle offset for the Z1 nozzle.
Standard setting: 0
257. MG4NOXZ2 Needle_offset_X_Z2 (-32768 to 32767) [pulse] = 0
Specify the X coordinate of the needle offset for the Z2 nozzle.
Standard setting: 0
258. MG4NOXZ3 Needle_offset_X_Z3 (-32768 to 32767) [pulse] = 0
Specify the X coordinate of the needle offset for the Z3 nozzle.
Standard setting: 0
259. MG4NOYZ1 Needle_offset_Y_Z1 (-32768 to 32767) [pulse] = 0
Specify the Y coordinate of the needle offset for the Z1 nozzle.
Standard setting: 0