Chapter 3 3.2 Definitions of Proper Data Edition 1.1 3-17 GL-541E Level 3 Reference 43. MG4AUTOS Auto_Start = 0 Specify whether the machine enters automatic operation without the START button being pressed when changeove…

Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-16 GL-541E Level 3 Reference
26. MG4CVAL Conveyor_Adj_Limit (0.05 to 1.00) [mm] = 50
Specify the tolerance for the conveyor width setting when using automatic
conveyor width adjustment.
Standard setting: 50
27. MG4CVSO Conveyor_Stop_Offset (0.00 to 2.00) [mm] = 30
Specify the offset value for stopping the motor at the target position when using
automatic conveyor width adjustment.
Standard setting: 30
28. MG4CVAT Conveyor_adj_Timer (0 to 120000) [msec] = 60000
Specify the time for automatic conveyor width adjustment. If this time is
exceeded, a time-up error occurs.
Standard setting: 60000
29. MG4WMAL Width_Max_Limit (0.00 to 655.35) [mm] = 360
Specify the maximum conveyor width.
Standard setting: 360.00
30. MG4WMIL Width_Min_Limit (0.00 to 655.35) [mm] = 50
Specify the minimum conveyor width.
Standard setting: 50.00
40. MG4LMS LMS_Flag = 0
Specify whether the machine is HELPS-compatible or not HELPS-compatible.
[0] Off: Non HELPS-compatible machine
[1] On: HELPS-compatible machine
Standard setting: 0
41. MG4CELL Cell_Status = 0
Specify the cell status.
[0] Unit: Unit cell
[1] Active: Active cell
[2] Passive: Passive cell
Standard setting: 0
42. MG4CHGOM Change_Over_Mode (0 to 200) = 0
Specify the board type report for a HELPS machine.
[0]: Manual terminate
[2]: Pattern code (upper surface)
[4]: Bar code 1 (upper surface)
[5]: Bar code 2 (lower surface)
[25]: Bar code 3 (when using two bar codes; both surfaces)
Standard setting: 0

Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-17 GL-541E Level 3 Reference
43. MG4AUTOS Auto_Start = 0
Specify whether the machine enters automatic operation without the START
button being pressed when changeover is complete on a HELPS machine.
[0] No: After changeover is complete, the START button is enabled.
[1] Yes: After changeover is complete, the machine starts automatically.
Standard setting: No
44. MG4BKPC Backup_Plate_Check = 0
Specify whether a back-up plate change request is issued.
[0] No: No backup plate change request is issued.
[1] Yes: A backup plate change request is issued.
Standard setting: No
45. MG4CMLS Command_Line_Status = 0
Specify the mode of transmission with the LAN.
[0] RS232C: Use RS232C
[1] LAN: Use LAN
[2] ETHERNET: Use ETHERNET
Standard setting: 0
Note: Do not set LAN or ETHERNET as they are not available.
46. MG4CMLP Command_Line _Port (0 to 30) = 0
Specify the communication board port number when an RS-232C is used.
0: Command line is not used.
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
48. MG4BUZW Buzzer_Warning = 0
Specify whether a buzzer sounds when HELPS changeover is performed.
[0] On: Buzzer will sound.
[1] Off: Buzzer will not sound.
Standard setting: 0
49. MG4PROT Process_Timer (0 to 120000) [msec]
Specify the protocol timer value.
Standard setting: 10000
Note: A setting of about 2000 ms is appropriate.
50. MG4RDT Reader Type (0 to 9) = 0
Specify the code reader type when using a code reader to identify the board types
on a HELPS machine.
[0]: Fuji standard bar-code reader
[1]: Fuji standard pattern code reader
[2]: AT&T bar-code reader
[3]: Keyence bar-code reader
Standard setting: 0

Chapter 3 3.2 Definitions of Proper Data
Edition 1.1 3-18 GL-541E Level 3 Reference
51. MG4CDRT Code_Reader_Timer (0 to 120000) [msec] = 10000
Specify the time to read the board type code.
Standard setting: 10000
52. MG4CDRR Code_Reader_Retry (0 to 10) = 0
Specify the number of times an attempt is made to read the board type code if an
error occurs on the first attempt.
Standard setting: 0
53. MG4RD1P Reader1_Port_No. (0 to 30) = 0
Specify the communication board port number when the upper surface code
reader is being used.
0: Command line is not used.
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
54. MG4RD2P Reader2_Port_No (0 to 30) = 0
Specify the communication board port number when the lower surface code
reader is being used.
0: Command line is not used.
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board
Standard setting: 0
55. MG4PCBCT PCB_Code_Terminal = 0
Specify whether a code read recovery terminal is used or not.
[0] Non: Not used
[1] Yes: Used
Standard setting: 0
57. MG4CDTP Code_Terminal_Port (0 to 30) = 0
Specify the communication board port number when the code read recovery
terminal is used.
0: Command line is not used.
11 ~ 16: Port numbers 1 to 6 on the first VM1440 board.
Standard setting: 0